Literature DB >> 22569953

Concurrent recordings of bladder afferents from multiple nerves using a microfabricated PDMS microchannel electrode array.

Evangelos Delivopoulos1, Daniel J Chew, Ivan R Minev, James W Fawcett, Stéphanie P Lacour.   

Abstract

In this paper we present a compliant neural interface designed to record bladder afferent activity. We developed the implant's microfabrication process using multiple layers of silicone rubber and thin metal so that a gold microelectrode array is embedded within four parallel polydimethylsiloxane (PDMS) microchannels (5 mm long, 100 μm wide, 100 μm deep). Electrode impedance at 1 kHz was optimized using a reactive ion etching (RIE) step, which increased the porosity of the electrode surface. The electrodes did not deteriorate after a 3 month immersion in phosphate buffered saline (PBS) at 37 °C. Due to the unique microscopic topography of the metal film on PDMS, the electrodes are extremely compliant and can withstand handling during implantation (twisting and bending) without electrical failure. The device was transplanted acutely to anaesthetized rats, and strands of the dorsal branch of roots L6 and S1 were surgically teased and inserted in three microchannels under saline immersion to allow for simultaneous in vivo recordings in an acute setting. We utilized a tripole electrode configuration to maintain background noise low and improve the signal to noise ratio. The device could distinguish two types of afferent nerve activity related to increasing bladder filling and contraction. To our knowledge, this is the first report of multichannel recordings of bladder afferent activity.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22569953     DOI: 10.1039/c2lc21277c

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  12 in total

1.  Neural Recording and Modulation Technologies.

Authors:  Ritchie Chen; Andres Canales; Polina Anikeeva
Journal:  Nat Rev Mater       Date:  2017-01-04       Impact factor: 66.308

2.  Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays.

Authors:  Zhengtuo Zhao; Xue Li; Fei He; Xiaoling Wei; Shengqing Lin; Chong Xie
Journal:  J Neural Eng       Date:  2019-02-08       Impact factor: 5.379

3.  Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees.

Authors:  Akhil Srinivasan; Mayank Tahilramani; John T Bentley; Russell K Gore; Daniel C Millard; Vivek J Mukhatyar; Anish Joseph; Adel S Haque; Garrett B Stanley; Arthur W English; Ravi V Bellamkonda
Journal:  Biomaterials       Date:  2014-12-09       Impact factor: 12.479

4.  In vitro multichannel single-unit recordings of action potentials from mouse sciatic nerve.

Authors:  L Chen; S J Ilham; T Guo; S Emadi; B Feng
Journal:  Biomed Phys Eng Express       Date:  2017-07-26

Review 5.  Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring.

Authors:  Hadaate Ullah; Md A Wahab; Geoffrey Will; Mohammad R Karim; Taisong Pan; Min Gao; Dakun Lai; Yuan Lin; Mahdi H Miraz
Journal:  Biosensors (Basel)       Date:  2022-08-11

Review 6.  Flexible Electronics and Devices as Human-Machine Interfaces for Medical Robotics.

Authors:  Wenzheng Heng; Samuel Solomon; Wei Gao
Journal:  Adv Mater       Date:  2022-02-25       Impact factor: 32.086

Review 7.  Implantable neurotechnologies: a review of integrated circuit neural amplifiers.

Authors:  Kian Ann Ng; Elliot Greenwald; Yong Ping Xu; Nitish V Thakor
Journal:  Med Biol Eng Comput       Date:  2016-01-22       Impact factor: 2.602

Review 8.  Brain tissue responses to neural implants impact signal sensitivity and intervention strategies.

Authors:  Takashi D Y Kozai; Andrea S Jaquins-Gerstl; Alberto L Vazquez; Adrian C Michael; X Tracy Cui
Journal:  ACS Chem Neurosci       Date:  2015-01-12       Impact factor: 4.418

Review 9.  Emerging neural stimulation technologies for bladder dysfunctions.

Authors:  Jee Woong Lee; Daejeong Kim; Sangjin Yoo; Hyungsup Lee; Gu-Haeng Lee; Yoonkey Nam
Journal:  Int Neurourol J       Date:  2015-03-26       Impact factor: 2.835

10.  Flexible and stretchable nanowire-coated fibers for optoelectronic probing of spinal cord circuits.

Authors:  Chi Lu; Seongjun Park; Thomas J Richner; Alexander Derry; Imogen Brown; Chong Hou; Siyuan Rao; Jeewoo Kang; Chet T Mortiz; Yoel Fink; Polina Anikeeva
Journal:  Sci Adv       Date:  2017-03-29       Impact factor: 14.136

View more