Literature DB >> 22569164

Development of aortic insufficiency in patients supported with continuous flow left ventricular assist devices.

Behzad Soleimani1, Annick Haouzi, Angela Manoskey, Edward R Stephenson, Aly El-Banayosy, Walter E Pae.   

Abstract

Development of aortic insufficiency (AI) in patients supported with continuous flow left ventricular assist devices (LVAD) can adversely affect pump performance. In this study, we examined the incidence of new AI after LVAD implant at our institution. Pre- and postoperative echocardiograms of 66 patients who received HeartMate II or Heartware LVAD at our institution since June 2008 were reviewed for presence of new AI. Median LVAD support duration was 221 days. New AI developed in 6 patients (9.5%) after a median time of 374.5 days of support. There were no cases of severe or symptomatic AI. There was no significant difference between the AI incidence between HeartMate II and Heartware recipients. For patients who remained on LVAD support at 6 and 12 months, freedom from AI was 100% and 68.4%, respectively. Age, destination therapy status, and duration of support were predictors of new AI after LVAD implant. In conclusion, AI develops frequently during long-term support with continuous flow LVADs, particularly in those supported for longer than 6 months. As we move to the era of long-term LVAD support and destination therapy, further studies with longer follow-ups are required to determine the progression and clinical significance of AI in these patients.

Entities:  

Mesh:

Year:  2012        PMID: 22569164     DOI: 10.1097/MAT.0b013e318251cfff

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  12 in total

Review 1.  Management of aortic insufficiency in the continuous flow left ventricular assist device population.

Authors:  Jonathan Holtz; Jeffrey Teuteberg
Journal:  Curr Heart Fail Rep       Date:  2014-03

Review 2.  [Ventricular long-term support with implantable continuous flow pumps: on the way to a gold standard in the therapy of terminal heart failure].

Authors:  T Krabatsch; E Potapov; S Soltani; M Dandel; V Falk; C Knosalla
Journal:  Herz       Date:  2015-04       Impact factor: 1.443

Review 3.  Impact of adverse events on ventricular assist device outcomes.

Authors:  Aleksandar Adzic; Snehal R Patel; Simon Maybaum
Journal:  Curr Heart Fail Rep       Date:  2013-03

Review 4.  Contemporary Perspectives in Durable Mechanical Circulatory Support: What Did We Learn in the Last 3 Years?

Authors:  Jayant Raikhelkar; Nir Uriel
Journal:  Curr Cardiol Rep       Date:  2018-01-29       Impact factor: 2.931

Review 5.  Physiology and Clinical Utility of HeartMate Pump Parameters.

Authors:  Mark N Belkin; Viktoriya Kagan; Colleen Labuhn; Sean P Pinney; Jonathan Grinstein
Journal:  J Card Fail       Date:  2021-12-31       Impact factor: 6.592

6.  Preservation of native aortic valve flow and full hemodynamic support with the TORVAD using a computational model of the cardiovascular system.

Authors:  Jeffrey R Gohean; Mitchell J George; Kay-Won Chang; Erik R Larson; Thomas D Pate; Mark Kurusz; Raul G Longoria; Richard W Smalling
Journal:  ASAIO J       Date:  2015 May-Jun       Impact factor: 2.872

7.  Novel echocardiographic parameters of aortic insufficiency in continuous-flow left ventricular assist devices and clinical outcome.

Authors:  Jonathan Grinstein; Eric Kruse; Gabriel Sayer; Savitri Fedson; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Takeyoshi Ota; Valluvan Jeevanandam; Victor Mor-Avi; Roberto M Lang; Nir Uriel
Journal:  J Heart Lung Transplant       Date:  2016-05-20       Impact factor: 10.247

Review 8.  Current Role of the Total Artificial Heart in the Management of Advanced Heart Failure.

Authors:  Nathaniel Melton; Behzad Soleimani; Robert Dowling
Journal:  Curr Cardiol Rep       Date:  2019-11-22       Impact factor: 2.931

9.  Aortic Insufficiency During Contemporary Left Ventricular Assist Device Support: Analysis of the INTERMACS Registry.

Authors:  Lauren K Truby; A Reshad Garan; Raymond C Givens; Brian Wayda; Koji Takeda; Melana Yuzefpolskaya; Paolo C Colombo; Yoshifumi Naka; Hiroo Takayama; Veli K Topkara
Journal:  JACC Heart Fail       Date:  2018-11       Impact factor: 12.035

10.  Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography.

Authors:  Zumrut Tuba Demirozu; Nurcan Arat; Deniz Suha Kucukaksu
Journal:  Cardiovasc J Afr       Date:  2016 Jul/Aug       Impact factor: 1.167

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.