Deformation of implant abutments after framework connection using strain gauges.

Henrique Hollweg1, Letícia Borges Jacques, Márcio da Silva Moura, Vinícius Cappo Bianco, Edson Antonio Capello Souza, José Henrique Rubo.   

Abstract

When a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n  =  5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22568468     DOI: 10.1563/AAID-JOI-D-10-00068

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

1.  Effect of veneering material on the deformation suffered by implant-supported fixed prosthesis framework.

Authors:  Antônio Francisco Grando; Carlos Eduardo Edwards Rezende; Edson Antônio Capello Sousa; José Henrique Rubo
Journal:  J Appl Oral Sci       Date:  2014-06       Impact factor: 2.698

2.  Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

Authors:  Ipsha Singh; K Chandrasekharan Nair; Jayakar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.