Literature DB >> 22565506

Basic vapor exposure for tuning the charge state distribution of proteins in negative electrospray ionization: elucidation of mechanisms by fluorescence spectroscopy.

Marion Girod1, Rodolphe Antoine, Philippe Dugourd, Craig Love, Alex Mordehai, George Stafford.   

Abstract

Manipulation for simplifying or increasing the observed charge state distributions of proteins can be highly desirable in mass spectrometry experiments. In the present work, we implemented a vapor introduction technique to an Agilent Jet Stream ESI (Agilent Technologies, Santa Clara, CA, USA) source. An apparatus was designed to allow for the enrichment of the nitrogen sheath gas with basic vapors. An optical setup, using laser-induced fluorescence and a pH-chromic dye, permits the pH profiling of the droplets as they evaporate in the electrospray plume. Mechanisms of pH droplet modification and its effect on the protein charging phenomenon are elucidated. An important finding is that the enrichment with basic vapors of the nitrogen sheath gas, which surrounds the nebulizer spray, leads to an increase in the spray current. This is attributed to an increase in the electrical conductivity of water-amine enriched solvent at the tip exit. Here, the increased current results in a generation of additional electrolytically produced OH(-) ions and a corresponding increase in the pH at the tip exit. Along the electrospray plume, the pH of the droplets increases due to both droplet evaporation and exposure to basic vapors from the seeded sheath gas. The pH evolution in the ESI plume obtained using pure and basic seeded sheath gas was correlated with the evolution of the charge state distribution observed in mass spectra of proteins, in the negative ion mode. Taking advantage of the Agilent Jet Stream source geometry, similar protein charge state distributions and ion intensities obtained with basic initial solutions, can be obtained using native solution conditions by seeding the heated sheath gas with basic vapors.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22565506     DOI: 10.1007/s13361-012-0375-1

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  37 in total

1.  Effects of solvent on the maximum charge state and charge state distribution of protein ions produced by electrospray ionization.

Authors:  A T Iavarone; J C Jurchen; E R Williams
Journal:  J Am Soc Mass Spectrom       Date:  2000-11       Impact factor: 3.109

2.  Protein structural effects in gas phase ion/molecule reactions with diethylamine.

Authors:  R R Loo; J A Loo; H R Udseth; J L Fulton; R D Smith
Journal:  Rapid Commun Mass Spectrom       Date:  1992-03       Impact factor: 2.419

Review 3.  Studies of biomolecular conformations and conformational dynamics by mass spectrometry.

Authors:  Igor A Kaltashov; Stephen J Eyles
Journal:  Mass Spectrom Rev       Date:  2002 Jan-Feb       Impact factor: 10.946

4.  Using the electrochemistry of the electrospray ion source.

Authors:  Gary J Van Berkel; Vilmos Kertesz
Journal:  Anal Chem       Date:  2007-08-01       Impact factor: 6.986

5.  Electrochemically induced pH changes resulting in protein unfolding in the ion source of an electrospray mass spectrometer.

Authors:  L Konermann; E A Silva; O F Sogbein
Journal:  Anal Chem       Date:  2001-10-15       Impact factor: 6.986

6.  Proton-transfer reactions of mass-selected multiply charged ions.

Authors:  A P Hunter; J C Severs; F M Harris; D E Games
Journal:  Rapid Commun Mass Spectrom       Date:  1994-05       Impact factor: 2.419

Review 7.  Top-down mass spectrometry: recent developments, applications and perspectives.

Authors:  Weidong Cui; Henry W Rohrs; Michael L Gross
Journal:  Analyst       Date:  2011-08-08       Impact factor: 4.616

8.  Mechanism of charging and supercharging molecules in electrospray ionization.

Authors:  Anthony T Iavarone; Evan R Williams
Journal:  J Am Chem Soc       Date:  2003-02-26       Impact factor: 15.419

9.  Evolution of the solvent polarity in an electrospray plume.

Authors:  Rui Wang; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2009-11-06       Impact factor: 3.109

10.  Spectral and photophysical studies of benzo[c]xanthene dyes: dual emission pH sensors.

Authors:  J E Whitaker; R P Haugland; F G Prendergast
Journal:  Anal Biochem       Date:  1991-05-01       Impact factor: 3.365

View more
  2 in total

1.  Joule Heating and Thermal Denaturation of Proteins in Nano-ESI Theta Tips.

Authors:  Feifei Zhao; Sarah M Matt; Jiexun Bu; Owen G Rehrauer; Dor Ben-Amotz; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-11       Impact factor: 3.109

2.  The Evolution of Electrospray Generated Droplets is Not Affected by Ionization Mode.

Authors:  Piia Liigand; Agnes Heering Suu; Karl Kaupmees; Ivo Leito; Marion Girod; Rodolphe Antoine; Anneli Kruve
Journal:  J Am Soc Mass Spectrom       Date:  2017-07-25       Impact factor: 3.109

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.