Literature DB >> 22560348

Chemical anchoring of lauryl methacrylate-based reversed phase monolith to 1/16″ o.d. polyetheretherketone tubing.

Shin Shu1, Hiroharu Kobayashi, Masaki Okubo, Akhmad Sabarudin, Michio Butsugan, Tomonari Umemura.   

Abstract

In this paper, we describe a method for the preparation of easy-to-use reversed-phase monolithic microbore columns. Polyetheretherketone (PEEK) tubing with an outer diameter of 1/16″ and an inner diameter of 1.0 mm was used as a column housing (empty column), and in it lauryl methacrylate (LMA) was copolymerized with ethylene dimethacrylate (EDMA). In order to chemically anchor the polymer monolith to the tube wall, the inner wall surface was pretreated by the following two-step procedure. (1) 50% sulfuric acid was filled into the PEEK tubing and left to stand for 6 h to generate sulfonate groups on the surface. (2) After washing with Milli-Q water, the sulfonated PEEK surface was brought into contact with 1 M glycidyl methacrylate in dichloromethane (or acetone) at 40°C for 4 h to introduce methacryloyl groups via the reaction of sulfonate groups and epoxy groups. Mechanical strength and column efficiency of the resulting monoliths were evaluated through the separation of a series of alkylbenzenes in acetonitrile-water (50:50, v/v) eluent over the flow rate range of 50-750 μL/min (corresponding to 1.7-25.5 mm/s). The poly(LMA-co-EDMA) monolith provided acceptable column efficiency of 2000 theoretical plates/10 cm (HETP value of 50 μm) for amylbenzene (separation factor k=40) and low flow resistance of 0.5 MPa/10 cm at a normal flow rate of 50 μL/min. The methacryloylated PEEK tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 15 MPa, allowing rapid separation at a 15-20 fold higher flow rate than normal.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22560348     DOI: 10.1016/j.chroma.2012.04.030

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Shear bond strength of composite resin to high performance polymer PEKK according to surface treatments and bonding materials.

Authors:  Ki-Sun Lee; Myoung-Sik Shin; Jeong-Yol Lee; Jae-Jun Ryu; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

2.  Polystyrene-co-Divinylbenzene PolyHIPE Monoliths in 1.0 mm Column Formats for Liquid Chromatography.

Authors:  Sidratul Choudhury; Laurence Fitzhenry; Blánaid White; Damian Connolly
Journal:  Materials (Basel)       Date:  2016-03-18       Impact factor: 3.623

3.  Cobalt (II)-Mediated Molecularly Imprinted Polymer as a Monolithic Stationary Phase for Separation of Racemic Citronellal by Liquid Chromatography.

Authors:  Suci Amalia; Nilna Assasiatur Rafika; Shova Audinia Hardiyanti; Adi Dwi Ashari; Bhisma Wildan Khabibi; Elvina Dhiaul Iftitah; Warsito Warsito; Aliya Nur Hasanah; Akhmad Sabarudin
Journal:  ScientificWorldJournal       Date:  2022-02-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.