Literature DB >> 22560270

Comparison of sitting face-to-face intubation (two-person technique) with standard oral-tracheal intubation in novices: a mannequin study.

Donna Venezia1, Andrew Wackett, Alexander Remedios, Victor Tarsia.   

Abstract

BACKGROUND: Few studies have evaluated the impact of the upright position on the success of oral-tracheal intubation. Yet, for patients with airway difficulties (i.e, active intraoral bleeding or morbidly obese), the upright position may both benefit the patient and facilitate intubation.
OBJECTIVES: We compared the success rates of subjects performing standard intubation to a modified version of the sitting face-to-face oral-tracheal intubation technique on a simulation model. We also reviewed the possible advantages and limitations of the sitting face-to-face intubation technique.
METHODS: Volunteer medical and paramedical students were given instruction, then tested, performing in random order both standard oral-tracheal and two-person sitting face-to-face oral-tracheal intubation on full-bodied mannequins. Observers reviewed video recordings, noting the number of successful intubations and the time to completion of each procedure at 15, 20, and 30 s.
RESULTS: All of the sitting face-to-face intubations were successful, 53/53 (100%, 95% confidence interval [CI] 93-100%); whereas of the 53 subjects who performed standard intubation, 48 were successful (91%, 95% CI 80-96%). The difference between successful intubations using the standard vs. sitting face-to-face technique was 9% (95% CI 1.3-9.4%, p=0.025). At times 15 and 20 s, medical student subjects who successfully performed both techniques were less successful at completing the procedure when performing the standard technique as compared to the sitting face-to-face technique (p=0.016). A post-procedural survey found that the majority of subjects preferred the sitting technique.
CONCLUSION: Subjects were significantly more successful at performing and preferred the sitting face-to-face intubation when compared to standard intubation.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22560270     DOI: 10.1016/j.jemermed.2012.03.019

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  6 in total

1.  Cross-over study of novice intubators performing endotracheal intubation in an upright versus supine position.

Authors:  Joseph S Turner; Timothy J Ellender; Enola R Okonkwo; Tyler M Stepsis; Andrew C Stevens; Christopher S Eddy; Erik G Sembroski; Anthony J Perkins; Dylan D Cooper
Journal:  Intern Emerg Med       Date:  2016-06-14       Impact factor: 3.397

2.  Face-to-face tracheal intubation in adult patients: a comparison of the Airtraq™, Glidescope™ and Fastrach™ devices.

Authors:  Zehra Ipek Arslan; Volkan Alparslan; Pınar Ozdal; Kamil Toker; Mine Solak
Journal:  J Anesth       Date:  2015-07-29       Impact factor: 2.078

3.  A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope.

Authors:  Hyun Young Choi; Young Min Oh; Gu Hyun Kang; Hyunggoo Kang; Yong Soo Jang; Wonhee Kim; Euichung Kim; Young Soon Cho; Hyukjoong Choi; Hyunjong Kim; Gyoung Yong Kim
Journal:  Biomed Res Int       Date:  2015-06-16       Impact factor: 3.411

Review 4.  Nasal intubation: A comprehensive review.

Authors:  Varun Chauhan; Gaurav Acharya
Journal:  Indian J Crit Care Med       Date:  2016-11

5.  Sitting Nasal Intubation With Fiberoptic in an Elective Mandible Surgery Under General Anesthesia.

Authors:  Seyyed Hassan Etemadi; Amir Bahrami; Ali Mohammad Farahmand; Mohammad Mahdi Zamani
Journal:  Anesth Pain Med       Date:  2015-11-28

6.  Face-to-face intubation using a lightwand in a patient with severe thoracolumbar kyphosis: a case report.

Authors:  Hyungmo Jeong; Minchul Chae; Hyungseok Seo; Jae-Woo Yi; Jong-Man Kang; Bong-Jae Lee
Journal:  BMC Anesthesiol       Date:  2018-07-21       Impact factor: 2.217

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.