| Literature DB >> 22560162 |
Changlong Hao1, Liguang Xua, Changrui Xing, Hua Kuang, Libing Wang, Chuanlai Xu.
Abstract
In this study, we report a new fluorogenic sensor based on fluorescence resonance energy transfer (FRET) for detection of heavy metal ions in aqueous solution. The method showed the advantage of being simple, highly sensitive and selective, and rapid. The donor (CdTe QDs) and acceptor (TAMRA or Cy5) are brought into close proximity to one another due to Hg(2+) and Ag(+) form strong and stable T-Hg(2+)-T complexes and C-Ag(+)-C complexes, which quenches the fluorescent intensity of CdTe QDs and enables the energy transfer from donor to acceptor. This sensor showed high sensitivity and selectivity when only one kind of ion (Ag(+) or Hg(2+)) exists. Furthermore, the assay can also simultaneously detect Ag(+) and Hg(2+) in water media with the limit of detection (LOD) of 2.5 and 1.8 nM, separately, which satisfactorily meets the sensitivity demands of Environmental Protection Agency (EPA) and World Health Organization (WHO). This assay also exhibits excellent selectivity toward Ag(+) and Hg(2+). Therefore, this method is of great practical and theoretical importance for detecting heavy metal ions in aqueous solution.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22560162 DOI: 10.1016/j.bios.2012.04.008
Source DB: PubMed Journal: Biosens Bioelectron ISSN: 0956-5663 Impact factor: 10.618