Literature DB >> 22560004

Optimised in vitro applicable loads for the simulation of lateral bending in the lumbar spine.

Marcel Dreischarf1, Antonius Rohlmann, Georg Bergmann, Thomas Zander.   

Abstract

In in vitro studies of the lumbar spine simplified loading modes (compressive follower force, pure moment) are usually employed to simulate the standard load cases flexion-extension, axial rotation and lateral bending of the upper body. However, the magnitudes of these loads vary widely in the literature. Thus the results of current studies may lead to unrealistic values and are hardly comparable. It is still unknown which load magnitudes lead to a realistic simulation of maximum lateral bending. A validated finite element model of the lumbar spine was used in an optimisation study to determine which magnitudes of the compressive follower force and bending moment deliver results that fit best with averaged in vivo data. The best agreement with averaged in vivo measured data was found for a compressive follower force of 700 N and a lateral bending moment of 7.8 Nm. These results show that loading modes that differ strongly from the optimised one may not realistically simulate maximum lateral bending. The simplified but in vitro applicable loading cannot perfectly mimic the in vivo situation. However, the optimised magnitudes are those which agree best with averaged in vivo measured data. Its consequent application would lead to a better comparability of different investigations.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22560004     DOI: 10.1016/j.medengphy.2012.04.002

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  6 in total

1.  Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann; Hadi N Boustani
Journal:  Eur Spine J       Date:  2011-10-20       Impact factor: 3.134

2.  Parameters influencing the outcome after total disc replacement at the lumbosacral junction. Part 1: misalignment of the vertebrae adjacent to a total disc replacement affects the facet joint and facet capsule forces in a probabilistic finite element analysis.

Authors:  A Rohlmann; S Lauterborn; M Dreischarf; H Schmidt; M Putzier; P Strube; T Zander
Journal:  Eur Spine J       Date:  2013-07-20       Impact factor: 3.134

3.  Effect of Graded Facetectomy on Lumbar Biomechanics.

Authors:  Zhi-Li Zeng; Rui Zhu; Yang-Chun Wu; Wei Zuo; Yan Yu; Jian-Jie Wang; Li-Ming Cheng
Journal:  J Healthc Eng       Date:  2017-02-19       Impact factor: 2.682

4.  Biomechanical Investigation Between Rigid and Semirigid Posterolateral Fixation During Daily Activities: Geometrically Parametric Poroelastic Finite Element Analyses.

Authors:  Mohammad Nikkhoo; Meng-Ling Lu; Wen-Chien Chen; Chen-Ju Fu; Chi-Chien Niu; Yang-Hua Lin; Chih-Hsiu Cheng
Journal:  Front Bioeng Biotechnol       Date:  2021-04-01

5.  Biphasic Properties of PVAH (Polyvinyl Alcohol Hydrogel) Reflecting Biomechanical Behavior of the Nucleus Pulposus of the Human Intervertebral Disc.

Authors:  Minhyeok Heo; Seonghun Park
Journal:  Materials (Basel)       Date:  2022-01-31       Impact factor: 3.623

6.  Optimization of a lumbar interspinous fixation device for the lumbar spine with degenerative disc disease.

Authors:  Minhyeok Heo; Jihwan Yun; Hanjong Kim; Sang-Soo Lee; Seonghun Park
Journal:  PLoS One       Date:  2022-04-07       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.