Literature DB >> 22559660

Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.

J F Pavoni1, T L Pike, J Snow, L DeWerd, O Baffa.   

Abstract

PURPOSE: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit.
METHODS: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging.
RESULTS: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%∕3 mm and of 96.5% using 4%∕4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves.
CONCLUSIONS: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22559660     DOI: 10.1118/1.4704496

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

Review 1.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

Review 2.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

3.  Three-Dimensional Dosimetry by Optical-CT and Radiochromic Gel Dosimeter of a Multiple Isocenter Craniospinal Radiation Therapy Procedure.

Authors:  Matheus Antonio da Silveira; Juliana Fernandes Pavoni; Alexandre Colello Bruno; Gustavo Viani Arruda; Oswaldo Baffa
Journal:  Gels       Date:  2022-09-13
  3 in total