Comparison of micro-computed tomography and laser scanning for reverse engineering orthopaedic component geometries.

Matthew G Teeter1, Paul Brophy, Douglas D R Naudie, David W Holdsworth.   

Abstract

A significant amount of research has been undertaken to evaluate the function of implanted joint replacement components. Many of these studies require the acquisition of an accurate three-dimensional geometric model of the various implant components, using methods such as micro-computed tomography or laser scanning. The purpose of this study was to compare micro-computed tomography and laser scanning for obtaining component geometries. Five never-implanted polyethylene tibial inserts of one type were scanned with both micro-computed tomography and laser scanning to determine the repeatability of each method and measured for any deviations between the geometries acquired from the different scans. Overall, good agreement was found between the micro-computed tomography and laser scans, to within 71 microm on average. Micro-computed tomography was found to have superior repeatability to laser scanning (mean of 1 microm for micro-computed tomography versus 19 microm for laser scans). Micro-computed tomography may be preferred for visualizing small surface features, whereas laser scanning may be preferred for acquiring the geometry of metal objects to avoid computed tomography artifacts. In conclusion, the choice of micro-computed tomography versus laser scanning for acquiring orthopaedic component geometries will likely involve considerations of user preference, the specific application the scan will be used for, and the availability of each system.

Entities:  

Mesh:

Year:  2012        PMID: 22558841     DOI: 10.1177/0954411911434674

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT.

Authors:  N Ye; F Jian; W Lai
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

2.  Accuracy of in vitro mandibular volumetric measurements from CBCT of different voxel sizes with different segmentation threshold settings.

Authors:  Ting Dong; Lunguo Xia; Chenglin Cai; Lingjun Yuan; Niansong Ye; Bing Fang
Journal:  BMC Oral Health       Date:  2019-09-04       Impact factor: 2.757

3.  Comparability of skeletal fibulae surfaces generated by different source scanning (dual-energy CT scan vs. high resolution laser scanning) and 3D geometric morphometric validation.

Authors:  Annalisa Pietrobelli; Rita Sorrentino; Veronica Notariale; Stefano Durante; Stefano Benazzi; Damiano Marchi; Maria Giovanna Belcastro
Journal:  J Anat       Date:  2022-06-25       Impact factor: 2.921

Review 4.  Patents and intellectual property in orthopaedics and arthroplasty.

Authors:  Chika Edward Uzoigwe; Ahmed Shoaib
Journal:  World J Orthop       Date:  2020-01-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.