Recommendations and requirements for soap and hand rub dispensers in healthcare facilities.

Ojan Assadian1, Axel Kramer, Bärbel Christiansen, Martin Exner, Heike Martiny, Arno Sorger, Miranda Suchomel.   

Abstract

Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting. While requirements for the efficacy of hand disinfectants are defined in European testing norms such as the EN 1500 for hygienic hand disinfection or EN 12791 for surgical hand preparation, no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to enhance future improvement of dispenser functionality and design. Regardless of manufacture and design of a hand rub or liquid soap dispensers the following requirements shall be met in healthcare facilities:Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through "top-up" must not be possible. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturers' warnings must be possible at any time. The disperser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable chemicals and cleaning products. It must be possible to reprocess the dispenser and all of its permanent parts by applying machine based thermal disinfection at an A(0)-value of minimum 60 (e.g. 80°C/1 minute). Automatically portioning dispensers shall not fail during 200 hubs. The maximal allowed failure rate shall not exceed 1% (2 out of 200 consecutive hubs). A dispenser used for alcohol based hand rubs must allow keeping the alcohol concentration constant over a time period of 3 months. The maximum acceptable decrease in the concentration of the alcohol shall not exceed 5%. Liquid soap and hand rub dispensers with single-use pumps, ideally already mounted on the cartridge and to be discharged with the empty cartridge, are preferable. If pumps are used on the next consecutive cartridge, the manufacturer must provide the user with a detailed introduction for cleansing and reprocessing before further use. Because of forensic reasons it is recommended to place a good readable sign on the dispenser indicating e.g. "Apply alcohol based hand rubs only on the hand! Do not drink, avoid spraying into the eye or application on mucous membranes". It is regarded as an additional benefit, if the dispenser is able to document the consumption of hand rub or the frequency of hubs either mechanically or electronically.

Entities:  

Keywords:  alcohol-based hand rub; cartridge; dispenser; elbow; hand hygiene; healthcare facility; liquid soap; sensor

Year:  2012        PMID: 22558037      PMCID: PMC3334946          DOI: 10.3205/dgkh000187

Source DB:  PubMed          Journal:  GMS Krankenhhyg Interdiszip        ISSN: 1863-5245


Introduction

Hand hygiene is one of the most important measures to prevent transmission of infectious agents and plays a major role in prevention of infection in any type of healthcare setting [1]. Hand hygiene serves the protection of the patient, but at the same time also the safety of healthcare workers. While requirements for efficacy of hand disinfectants are defined in European norms such as the EN 1500 for hygienic hand disinfection [2], [3] or EN 12791 for surgical hand preparation [4], no specific recommendations for hand rub dispensers and liquid soap dispensers have been given yet. Thus, it is the aim to support both, the efforts of the German Society for Hospital Hygiene in the form of instructional videos on hand hygiene together with the Professional Association of German Surgeons (BDC) inaugurated concerted action “Patient protection through Hygiene” (http://www.dgkh.de/) as well as the Alliance “Clean Hands Campaign” („Aktion saubere Hände”) by amending hand hygiene issues to a hitherto little noticed and discussed topic: design and functional aspects of dispensers used in healthcare facilities. Therefore, the intention of the present recommendation on soap and hand rub dispensers in healthcare facilities is to close this gap and to foster future improvement of dispenser functionality and design.

Need for hand rub and soap dispensers and their optimal location in healthcare facilities

At any location within a healthcare facility, where the indication for regular conducting hand disinfection is given, a dispenser must be available. The dispenser must be freely accessible and positioned such, that its usage is easily possible. Relevant locations for dispensers may be close to or fixed at the patient bed in patient rooms, at the entrance of patient rooms, in examination and procedure rooms, in any specialized medical room dedicated for diagnostic and therapeutic procedures, but also in areas such as preparation rooms for baby formula, aseptic areas such as cornea transplant banks, or blood transfusion units, on trolleys used for storage and transport of wound care products, in the anterooms of isolation units and operating theatres, in sanitary rooms of medically used areas, or at the entrance of hospitals and intensive care units [5]. Provision of dispensers which fulfill the present recommendation in public sanitary rooms used only by visitors is not required. Since, however, also patients and visitors of a healthcare facility should be involved into performing hand hygiene it may be prudent to install dispensers visibly at the entrance area of a healthcare facility or high risk areas such as intensive care units together with easily understandable instructions for hand hygiene, such as in the form of pictograms. Abandonment of dispensers will automatically result in negligence of hand hygiene practices, since it will be difficult to disinfect contaminated hands during patient care. Pocket bottles can be accepted as a compromise, when dispensers cannot be installed because of difficult architectural situations. Pocket bottles, however, cannot substitute for the adequate availability of dispensers, since they allow hand hygiene only the person carrying the pocket bottle. Since performance of hand hygiene is also required for visitors and persons not regularly present in a healthcare facility, sole provision of staff with pocket bottles would result in a gap not allowing adequate compliance with hand hygiene practices.

Requirements for hand rub and liquid soap dispensers

Regardless of the manufacturer and the design of a hand rub or liquid soap dispenser the following requirements shall be met in healthcare facilities: Triggering the dispenser must be possible without using hands. Sensor- or elbow-operated dispensers both fulfill this requirement. Dispensers must be only refillable in a modality where the content, be it a hand rub or liquid soap, cannot be contaminated. This is achieved best by using replaceable cartridge systems. Refilling through “top-up” must not be possible [6]. The disperser should allow usage of different types of cartridges made by different manufacturers. Dispensers must be operated and maintained such that a microbial contamination of the pump nozzle may easily be avoided. It must be possible to identify the products used in a dispenser easily and without any manipulation. Identifying the type of product, be it a hand rub or a liquid soap, as well as reading the product's name and critical manufacturer warnings must be possible at any time [7]. The dispenser must allow identification of the level of the used product without any further manipulation at any time. The design of the dispenser must allow easy cleaning and disinfection the outside and inside of the dispenser. The manufacturer of the dispenser must provide the user with information on applicable chemicals and cleaning products. It must be possible to reprocess the dispenser and all of its permanent parts by applying machine based thermal disinfection at an A0-value of minimum 60 (e.g. 80°C/1 min). Automatically portioning dispensers shall not fail during 200 hubs. The maximal allowed failure rate shall not exceed 1% (2 out of 200 consecutive hubs). A dispenser used for alcohol based hand rubs must allow keeping the alcohol concentration constant over a time period of 3 months. The maximum acceptable decrease in the concentration of the alcohol shall not exceed 5%. Liquid soap and hand rub dispensers with single-use pumps, ideally already mounted on the cartridge and to be discharged with the empty cartridge, are preferable. If pumps are used on the next consecutive cartridge, the manufacturer must provide the user with a detailed introduction for cleansing and reprocessing before further use. Because of forensic reasons it is recommended to place a good readable sign on the dispenser indicating e.g. “Apply alcohol based hand rubs only on the hand! Do not drink, avoid spraying into the eye or application on mucous membranes” [8]. It is regarded as an additional benefit, if the dispenser is able to document the consumption of hand rub or the frequency of hubs either mechanically or electronically [9], [10].

Risk assessment of alcohol based hand rub dispensers

Dispensers filled with alcohol based hand rub cartridges do not pose a fire hazard in healthcare facilities. A questionnaire based survey analyzed reported fire outbreaks due to dispensers filled with alcohol based hand rubs among 788 healthcare facilities in Germany [11]. Taking the total time of usage of dispensers into consideration, a total of 25,038 hospital-days were included into the assessment. During this time period, only 7 incidences were reported. The reason for these 7 incidences included negligence (handling with burning cigarettes or candles close to the dispenser), vandalism, and one unsuccessful suicide attempt. A self-infliction of the dispenser was never observed. This observation allows the conclusion that dispensers filled with alcohol based hand rubs do not pose a fire hazard in healthcare facilities.

Notes

Competing interests

The authors declare that they have no competing interests.
  4 in total

1.  Microbial contamination of antiseptics and disinfectants.

Authors:  Somwang Danchaivijitr; Chertsak Dhiraputra; Yong Rongrungruang; Nitaya Srihapol; Varaporn Pumsuwan
Journal:  J Med Assoc Thai       Date:  2005-12

2.  Hand rub-associated fire incidents during 25,038 hospital-years in Germany.

Authors:  Axel Kramer; Gunter Kampf
Journal:  Infect Control Hosp Epidemiol       Date:  2007-05-10       Impact factor: 3.254

3.  Measuring hand hygiene compliance: a new frontier for improving hand hygiene.

Authors:  Andrew G Sahud; Nitin Bhanot
Journal:  Infect Control Hosp Epidemiol       Date:  2009-11       Impact factor: 3.254

4.  Evaluation of an electronic device for real-time measurement of alcohol-based hand rub use.

Authors:  John M Boyce; Timothea Cooper; Michael J Dolan
Journal:  Infect Control Hosp Epidemiol       Date:  2009-11       Impact factor: 3.254

  4 in total
  4 in total

1.  Infection control and quality management in dental medicine and maxillofacial surgery.

Authors:  Ojan Assadian; Axel Kramer; Georg Meyer
Journal:  GMS Krankenhhyg Interdiszip       Date:  2012-04-04

2.  Systemic mistakes in hand hygiene practice in Ukraine: detection, consequences and ways of elimination.

Authors:  Iryna Klymenko; Günter Kampf
Journal:  GMS Hyg Infect Control       Date:  2015-01-14

3.  Critical Reliability Issues of Common Type Alcohol-Based Handrub Dispensers.

Authors:  Száva Bánsághi; Hervé Soule; Chloé Guitart; Didier Pittet; Tamás Haidegger
Journal:  Antimicrob Resist Infect Control       Date:  2020-06-22       Impact factor: 4.887

4.  Adequacy of alcohol-based handrub solution production practice in response to COVID-19 in public hospitals found in Addis Ababa, Ethiopia: a multicentered cross-sectional study.

Authors:  Muluken Nigatu Selam; Regasa Bayisa; Andualem Ababu; Mahdi Abdella; Edessa Diriba; Minychel Wale; Assefa Mulu Baye
Journal:  J Pharm Policy Pract       Date:  2021-05-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.