Literature DB >> 22555578

Parallel imaging of the cervical spine at 3T: optimized trade-off between speed and image quality.

J Fruehwald-Pallamar1, P Szomolanyi, N Fakhrai, A Lunzer, M Weber, M M Thurnher, M Pallamar, S Trattnig, D Prayer, I M Noebauer-Huhmann.   

Abstract

BACKGROUND AND
PURPOSE: Patients with cervical spine syndrome often experience pain during the MR examination. Our aim was to compare the quality of cervical spine MR images obtained by parallel imaging with those of nonaccelerated images, with the goal of shortening the examination time while preserving adequate image quality.
MATERIALS AND METHODS: A phantom study and examinations of 10 volunteers and 26 patients were conducted on a clinical 3T scanner. Acquisitions included axial T2WI, sagittal T2WI, T1WI, and T2TIRM sequences. Nonaccelerated sequences and accelerated sequences with different numbers of averages and different accelerations, with a scanning time reduction of 67%, were performed. For quantitative analysis, the SNR was obtained from the phantom measurements, and the NU was calculated from the volunteer measurements. For qualitative analysis, 3 independent readers assessed the delineation of anatomic structures in volunteers and the visibility of degenerative disease in patients.
RESULTS: In the phantom study, as expected, the SNR of the nonaccelerated images was higher than the SNR of the same sequence with parallel imaging. In vivo, the NU was higher when applying fewer averages or parallel imaging, compared with the nonaccelerated images. The analysis of the subjective parameters in the volunteers and patients showed that a scanning time of 48% of the original protocol could be obtained by combining the following sequences: sagittal T1WI with 1 average; sagittal T2WI with acceleration factor 3; sagittal T2TIRM with acceleration factor 2; and axial T2* GRE with acceleration factor 2.
CONCLUSIONS: Parallel imaging of the cervical spine at 3T allows shortening of the examination time by 52%, preserving adequate image quality.

Entities:  

Mesh:

Year:  2012        PMID: 22555578      PMCID: PMC7964621          DOI: 10.3174/ajnr.A3101

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  26 in total

Review 1.  SMASH imaging.

Authors:  D K Sodickson; M A Griswold; P M Jakob
Journal:  Magn Reson Imaging Clin N Am       Date:  1999-05       Impact factor: 2.266

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Comparative study of fast MR imaging: quantitative analysis on image quality and efficiency among various time frames and contrast behaviors.

Authors:  Tao Li; Scott A Mirowitz
Journal:  Magn Reson Imaging       Date:  2002-07       Impact factor: 2.546

4.  Rapid musculoskeletal magnetic resonance imaging using integrated parallel acquisition techniques (IPAT)--initial experiences.

Authors:  B Romaneehsen; K Oberholzer; L P Müller; K-F Kreitner
Journal:  Rofo       Date:  2003-09

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

7.  MRI of degenerative lumbar spine disease: comparison of non-accelerated and parallel imaging.

Authors:  Ingo Nölte; Lars Gerigk; Marc A Brockmann; André Kemmling; Christoph Groden
Journal:  Neuroradiology       Date:  2008-05       Impact factor: 2.804

8.  The annual incidence and course of neck pain in the general population: a population-based cohort study.

Authors:  Pierre Côté; David J Cassidy; Linda J Carroll; Vicki Kristman
Journal:  Pain       Date:  2004-12       Impact factor: 6.961

9.  MRI of the abnormal cervical spinal cord using 2D spoiled gradient echo multiecho sequence (MEDIC) with magnetization transfer saturation pulse. A T2* weighted feasibility study.

Authors:  P Held; U Dorenbeck; J Seitz; R Fründ; H Albrich
Journal:  J Neuroradiol       Date:  2003-03       Impact factor: 3.447

Review 10.  Parallel magnetic resonance imaging.

Authors:  David J Larkman; Rita G Nunes
Journal:  Phys Med Biol       Date:  2007-03-09       Impact factor: 3.609

View more
  4 in total

1.  [Researcher of the month].

Authors:  Iris-Melanie Nöbauer-Huhmann
Journal:  Wien Klin Wochenschr       Date:  2013-11       Impact factor: 1.704

Review 2.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

3.  Clinical Utility of a Novel Ultrafast T2-Weighted Sequence for Spine Imaging.

Authors:  M B Keerthivasan; B Winegar; J L Becker; A Bilgin; M I Altbach; M Saranathan
Journal:  AJNR Am J Neuroradiol       Date:  2018-07-12       Impact factor: 3.825

4.  Effect of Physiological Noise on Thoracolumbar Spinal Cord Functional Magnetic Resonance Imaging in 3T Magnetic Field.

Authors:  Hamed Dehghani; Mohammad Ali Oghabian; Seyed Amir Hosein Batouli; Jalil Arab Kheradmand; Ali Khatibi
Journal:  Basic Clin Neurosci       Date:  2020-11-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.