Literature DB >> 22548281

Detection of aqueous glucose based on a cavity size- and optical-wavelength-independent continuous-wave photoacoustic technique.

S Camou1, T Haga, T Tajima, E Tamechika.   

Abstract

Toward the achievement of noninvasive and continuous monitoring of blood glucose level, we developed a new measurement method based on the continuous-wave photoacoustic (CW-PA) technique and performed the first validation in vitro with calibrated aqueous glucose solutions. The PA technique has been studied in the past but exclusively based on the pulse setup since the CW one exhibits dependence on the cavity dimensions, which is not compatible with the final application requirements. This paper describes a new strategy relying on the monitoring of the resonant-frequency relative shift induced by the change of glucose concentrations rather than amplitude signal levels at a fixed frequency. From in vitro results, we demonstrate a stable and reproducible response to glucose at various cavity dimensions and optical wavelengths, with a slope of 0.19 ±0.01%/g/dL. From theoretical considerations, this method is consistent with a relative acoustic velocity measurement, which also explains the aforementioned stability. The proposed method then resolves most of the issues usually associated with the CW-PA technique and makes it a potential alternative for the noninvasive and continuous monitoring of glycemia levels. However, experimental determination of sensor responses to albumin and temperature as two potential interferents shows similar levels, which points to the selectivity to glucose as a major issue we should deal with in future development.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22548281     DOI: 10.1021/ac203331w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Phase Difference Optimization of Dual-Wavelength Excitation for the CW-Photoacoustic-Based Noninvasive and Selective Investigation of Aqueous Solutions of Glucose.

Authors:  Serge Camou
Journal:  Sensors (Basel)       Date:  2015-07-07       Impact factor: 3.576

2.  Y-Net: Hybrid deep learning image reconstruction for photoacoustic tomography in vivo.

Authors:  Hengrong Lan; Daohuai Jiang; Changchun Yang; Feng Gao; Fei Gao
Journal:  Photoacoustics       Date:  2020-06-20

3.  Glucose Determination by a Single 1535 nm Pulsed Photoacoustic Technique: A Multiple Calibration for the External Factors.

Authors:  Lifeng Yang; Chulin Chen; Zhaojiang Zhang; Xin Wei
Journal:  J Healthc Eng       Date:  2022-09-19       Impact factor: 3.822

Review 4.  Signal amplification and quantification on lateral flow assays by laser excitation of plasmonic nanomaterials.

Authors:  Haihang Ye; Yaning Liu; Li Zhan; Yilin Liu; Zhenpeng Qin
Journal:  Theranostics       Date:  2020-03-15       Impact factor: 11.556

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.