Literature DB >> 22547765

Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study.

Raphaël P Martins1, Hugues Blangy, Lucian Muresan, Luc Freysz, Laurent Groben, Pierre-Yves Zinzius, Jérôme Schwartz, Jean-Marc Sellal, Etienne Aliot, Nicolas Sadoul.   

Abstract

AIMS: Little is known about the optimal number of antitachycardia pacing (ATP) attempts to programme in the fast ventricular tachycardia (FVT) zone. We sought to analyse the long-term efficacy and safety of programming a high number of ATP attempts for FVTs. METHODS AND
RESULTS: All patients receiving an implantable cardioverter/defibrillator (ICD) for coronary artery disease or dilated cardiomyopathy for primary and secondary prevention between 2000 and 2009 were prospectively included. Implantable cardioverter/defibrillators were programmed to deliver 10 ATP attempts for FVT cycle lengths (CLs) of 250-300 ms (200-240 b.p.m.) before shock delivery (5 bursts, then 5 ramps; 8-10 extrastimuli at 81-88% FVT CL; minimal pacing CL 180 ms). Among 770 patients included and followed for 40.6 ± 25.6 months, 137 (17.8%) experienced a total of 1839 FVTs, 1713 of which were ATP-terminated (unadjusted efficacy = 93.1%, adjusted = 81.7%), 106 ATP-accelerated (5.8%), and 20 ATP-resistant (1.1%). The majority of FVT episodes were successfully treated by one or two attempts (98.3%). However, patient-based analysis showed that 17 (12.4%), 8 (5.8%), and 5 patients (2.1%) had at least one episode treated by three or more, four or more, and five or more ATP attempts. The benefit of this strategy was reduced after five attempts. The majority of FVT episodes was asymptomatic and diagnosed at device interrogation during follow-up: syncope and pre-syncope occurred in only 0.2 and 0.4% of episodes, respectively.
CONCLUSION: Programming a high number of ATP attempts (up to five ATP attempts) in the FVT zone is both safe and efficient and could prevent shocks in numerous ICD recipients.

Entities:  

Mesh:

Year:  2012        PMID: 22547765     DOI: 10.1093/europace/eus107

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  9 in total

1.  [Inappropriate ICD therapies: All problems solved with MADIT-RIT?].

Authors:  Christof Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-04-21

Review 2.  Programming implantable cardioverter/defibrillators and outcomes.

Authors:  Fritz W Horlbeck; Joerg O Schwab
Journal:  F1000Prime Rep       Date:  2015-01-05

Review 3.  Optimal programming management of ventricular tachycardia storm in ICD patients.

Authors:  Zhiyong Qian; Jianghong Guo; Zhiyong Zhang; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  J Biomed Res       Date:  2015-01-05

4.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Authors:  Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesœs Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang
Journal:  J Arrhythm       Date:  2016-02-01

5.  Inappropriate implantable cardioverter defibrillator shocks-incidence, effect, and implications for driver licensing.

Authors:  Eiichi Watanabe; Katsunori Okajima; Akira Shimane; Tomoya Ozawa; Tetsuyuki Manaka; Itsuro Morishima; Toru Asai; Masahiko Takagi; Toshihiro Honda; Atsunobu Kasai; Eitaro Fujii; Kohei Yamashiro; Ritsuko Kohno; Haruhiko Abe; Takashi Noda; Takashi Kurita; Shigeyuki Watanabe; Hiroya Ohmori; Takashi Nitta; Yoshifusa Aizawa; Ken Kiyono; Ken Okumura
Journal:  J Interv Card Electrophysiol       Date:  2017-07-20       Impact factor: 1.900

6.  Duration of Inducible Ventricular Tachycardia Early After ST-Segment-Elevation Myocardial Infarction and Its Impact on Mortality and Ventricular Tachycardia Recurrence.

Authors:  Tejas Deshmukh; Sarah Zaman; Arun Narayan; Pramesh Kovoor
Journal:  J Am Heart Assoc       Date:  2020-06-23       Impact factor: 5.501

Review 7.  Perioperative Management of Patients with Cardiac Implantable Electronic Devices and Utility of Magnet Application.

Authors:  Tardu Özkartal; Andrea Demarchi; Maria Luce Caputo; Enrico Baldi; Giulio Conte; Angelo Auricchio
Journal:  J Clin Med       Date:  2022-01-28       Impact factor: 4.241

8.  Programming an ICD: It's time to change the defaults.

Authors:  A Thachil
Journal:  Indian Pacing Electrophysiol J       Date:  2018-03-15

9.  Myocardial Minimal Damage After Rapid Ventricular Pacing - the prospective randomized multicentre MyDate-Trial.

Authors:  Verena Semmler; Clara Deutschmann; Bernhard Haller; Carsten Lennerz; Amir Brkic; Christian Grebmer; Patrick Blazek; Severin Weigand; Martin Karch; Sonia Busch; Christof Kolb
Journal:  Sci Rep       Date:  2020-03-16       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.