Literature DB >> 22547745

Use of implantable cardioverter defibrillators in patients with left ventricular assist devices.

Stephen J Pettit1, Mark C Petrie, Derek T Connelly, Alan G Japp, John R Payne, Saleem Haj-Yahia, Roy S Gardner.   

Abstract

Patients with left ventricular assist devices (LVADs) are at high risk of sustained ventricular arrhythmias, but these may be remarkably well tolerated and the association with sudden death is unclear. Many patients who receive an LVAD already have an implantable cardioverter defibrillator (ICD). While it is standard practice to reactivate a previously implanted ICD in an LVAD recipient, this should include discussion of the revised risks and benefits of ICD therapy following LVAD implantation. In particular, patients should be warned that they might receive a significant number of ICD shocks that may not be life saving. When ICDs are reactivated, device programming should minimize the risk of repeated shocks for non-sustained or well-tolerated ventricular arrhythmias. Implantation of a primary prevention ICD after implantation of an LVAD is not supported by current evidence, poses potential risks, and should be the subject of a clinical trial before it becomes standard practice.

Entities:  

Mesh:

Year:  2012        PMID: 22547745     DOI: 10.1093/eurjhf/hfs062

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  4 in total

Review 1.  Wearable cardioverter defibrillator: Bridge or alternative to implantation?

Authors:  Jeremie Barraud; Jennifer Cautela; Morgane Orabona; Johan Pinto; Olivier Missenard; Marc Laine; Franck Thuny; Franck Paganelli; Laurent Bonello; Michael Peyrol
Journal:  World J Cardiol       Date:  2017-06-26

2.  Implantable cardioverter-defibrillator-related procedures and associated complications in continuous flow left ventricular assist device recipients: A multicenter experience.

Authors:  Ashwin Ravichandran; Naga Venkata K Pothineni; Jaimin R Trivedi; Henri Roukoz; Mustafa M Ahmed; Adarsh Bhan; Geetha Bhat; Jennifer Cowger; Amin Al Ahmad; Andrea Natale; Luigi Di Biase; Mark S Slaughter; Dhanunjaya Lakkireddy; Rakesh Gopinathannair
Journal:  Heart Rhythm O2       Date:  2021-12-17

3.  Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

Authors:  Selim Bozkurt; Frans N van de Vosse; Marcel C M Rutten
Journal:  J Med Biol Eng       Date:  2016-06-25       Impact factor: 1.553

4.  Cardiac Resynchronization Therapy and Clinical Outcomes in Continuous Flow Left Ventricular Assist Device Recipients.

Authors:  Rakesh Gopinathannair; Henri Roukoz; Adarsh Bhan; Ashwin Ravichandran; Mustafa M Ahmed; Dmitry Familtsev; Geetha Bhat; Jennifer Cowger; Munazzah Abdullah; Chirag Sandesara; Rahul Dhawan; Emma J Birks; Jaimin R Trivedi; Mark S Slaughter
Journal:  J Am Heart Assoc       Date:  2018-06-15       Impact factor: 5.501