Literature DB >> 22547382

Analysis of bone formation on porous and calcium phosphate-coated acetabular cups: a randomised clinical [18F]fluoride PET study.

Gösta Ullmark1, Jens Sörensen, Olle Nilsson.   

Abstract

We present a study using Fluoride-Positron Emission Tomography (F-PET/CT) to analyse new bone formation in periacetabular bone adjacent to press fit cups following THA. In 16 THA (8 patients) with bilateral hip osteoarthritis simultaneous bilateral total hip arthroplasty (THA) was performed, employing electrochemically applied calcium phosphate coated (HA) cups or porous-coated (PC) cups allocated at random to compare the two sides. A reference group of 13 individuals with a normal healthy hip was used to determine 'normal' bone metabolism. [18F]fluoride -PET/CT was used to analyze bone formation adjacent to the cups 1 week, 4 months and 12 months after surgery. Clinical and radiographic evaluation was performed preoperatively, postoperatively and at 2 years. Bone forming activity had a mean of 5.71, 4.69 and 3.47 SUV around the HA- and 5.04, 4.80 and 3.50 SUV around the PC-cups at 1 week, 4 months and 12 months respectively. Normal bone metabolism was 3.68 SUV. After 1 year activity had declined to normal levels for both groups. The clinical results were good in all cases. HA coating resulted in higher uptake indicating higher bone forming activity after 1 week. F-PET/CT is a valuable tool to analyse bone formation and secondary stabilisation of an acetabular cup.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22547382     DOI: 10.5301/HIP.2012.9233

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  7 in total

Review 1.  Evolving Role of Molecular Imaging with (18)F-Sodium Fluoride PET as a Biomarker for Calcium Metabolism.

Authors:  William Raynor; Sina Houshmand; Saeid Gholami; Sahra Emamzadehfard; Chamith S Rajapakse; Björn Alexander Blomberg; Thomas J Werner; Poul F Høilund-Carlsen; Joshua F Baker; Abass Alavi
Journal:  Curr Osteoporos Rep       Date:  2016-08       Impact factor: 5.096

2.  Knee osteochondritis dissecans-treatment technical aspects.

Authors:  Mats Brittberg
Journal:  J Orthop       Date:  2022-08-11

3.  Occult Hip Prosthetic Loosening Diagnosed by [18F] Fluoride-PET/CT.

Authors:  Gösta Ullmark
Journal:  Arthroplast Today       Date:  2020-08-01

Review 4.  Nuclear medicine and the failed joint replacement: Past, present, and future.

Authors:  Christopher J Palestro
Journal:  World J Radiol       Date:  2014-07-28

5.  Shining dead bone-cause for cautious interpretation of [18F]NaF PET scans.

Authors:  Magnus Bernhardsson; Olof Sandberg; Marcus Ressner; Jacek Koziorowski; Jonas Malmquist; Per Aspenberg
Journal:  Acta Orthop       Date:  2017-09-15       Impact factor: 3.717

6.  Analysis of bone mineralization on uncemented femoral stems by [18F]-fluoride-PET: a randomized clinical study of 16 hips in 8 patients.

Authors:  Gösta Ullmark; Olle Nilsson; Enn Maripuu; Jens Sörensen
Journal:  Acta Orthop       Date:  2013-03-19       Impact factor: 3.717

7.  Influence of Hydroxyapatite Coating for the Prevention of Bone Mineral Density Loss and Bone Metabolism after Total Hip Arthroplasty: Assessment Using 18F-Fluoride Positron Emission Tomography and Dual-Energy X-Ray Absorptiometry by Randomized Controlled Trial.

Authors:  Taro Tezuka; Naomi Kobayashi; Choe Hyonmin; Masatoshi Oba; Yushi Miyamae; Akira Morita; Yutaka Inaba
Journal:  Biomed Res Int       Date:  2020-02-22       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.