Surgical outcome of liver transection by the crush-clamping technique combined with Harmonic FOCUS™.

Naoto Gotohda1, Masaru Konishi, Shinichiro Takahashi, Takahiro Kinoshita, Yuichiro Kato, Taira Kinoshita.   

Abstract

BACKGROUND: New energy devices are constantly being introduced for all types of surgery, including liver surgery. These devices help surgeons perform operations. Meanwhile, intraoperative blood loss is a concern of liver surgeons. Various methods to reduce intraoperative bleeding during liver resection have been reported. There are some reports that the use of energy devices was effective for liver transection. Recently, the Harmonic FOCUS™ (HF), an ultrasonically activated device, was developed. The shape of the HF is similar to that of Kelly forceps. Hepatectomy can be performed by the clamp-crushing method using the HF instead of Kelly forceps. We obtained good results of liver resection with the HF, and report these outcomes in this study.
METHODS: From November 2009 to March 2011, a total of 51 patients underwent hepatectomy with the use of the HF. The control group consisted of 59 patients who underwent hepatectomy without the HF from February 2009 to September 2009. The surgical outcomes were evaluated and compared retrospectively.
RESULTS: Mean blood loss was 640 mL in the HF group compared to 1,176 mL in the control group. The number of patients needing a blood transfusion was smaller in the HF group (p = 0.02). Mean operative time was shorter in the HF group (171 vs. 235 min, p < 0.001). All these surgical outcomes were significantly better in the HF group. Postoperative morbidity was not increased in the HF group, and we could perform liver transection safely.
CONCLUSION: The crush-clamping method combined with the HF is effective for liver transection. Liver resection can be performed quickly using this method.

Entities:  

Mesh:

Year:  2012        PMID: 22547018     DOI: 10.1007/s00268-012-1624-y

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  13 in total

1.  Hepatic resection using the harmonic scalpel.

Authors:  H Sugo; Y Mikami; F Matsumoto; H Tsumura; Y Watanabe; K Kojima; S Futagawa
Journal:  Surg Today       Date:  2000       Impact factor: 2.549

2.  Current techniques of liver transection.

Authors:  Ronnie T P Poon
Journal:  HPB (Oxford)       Date:  2007       Impact factor: 3.647

3.  The Ligasure vessel sealer in liver resection: a pilot study.

Authors:  Antonio Chiappa; Andrew P Zbar; Emilio Bertani; Ugo Pace; Giuseppe Viale; Giancarlo Pruneri; Marco Venturino; MariaGiulia Zampino; Nicola Fazio; Guido Bonomo; Pasquale Misitano; Bruno Andreoni
Journal:  Hepatogastroenterology       Date:  2007-12

Review 4.  Techniques for liver parenchymal transection in liver resection.

Authors:  Kurinchi Selvan Gurusamy; Viniyendra Pamecha; Dinesh Sharma; Brian R Davidson
Journal:  Cochrane Database Syst Rev       Date:  2009-01-21

5.  Fusion technique for liver transection with Kelly-clysis and harmonic technology.

Authors:  P Jagannath; D G Chhabra; K R Sutariya; R C Shah
Journal:  World J Surg       Date:  2010-01       Impact factor: 3.352

6.  Randomized comparison of ultrasonic vs clamp transection of the liver.

Authors:  T Takayama; M Makuuchi; K Kubota; Y Harihara; A M Hui; K Sano; M Ijichi; K Hasegawa
Journal:  Arch Surg       Date:  2001-08

7.  Usefulness of LigaSure for liver resection: analysis by randomized clinical trial.

Authors:  Akio Saiura; Junji Yamamoto; Rintaro Koga; Yoshihiro Sakamoto; Norihiro Kokudo; Makoto Seki; Takuhiro Yamaguchi; Toshiharu Yamaguchi; Tetsuichiro Muto; Masatoshi Makuuchi
Journal:  Am J Surg       Date:  2006-07       Impact factor: 2.565

Review 8.  A model to predict survival in patients with end-stage liver disease.

Authors:  P S Kamath; R H Wiesner; M Malinchoc; W Kremers; T M Therneau; C L Kosberg; G D'Amico; E R Dickson; W R Kim
Journal:  Hepatology       Date:  2001-02       Impact factor: 17.425

9.  The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial.

Authors:  Mami Ikeda; Kiyoshi Hasegawa; Keiji Sano; Hiroshi Imamura; Yoshifumi Beck; Yasuhiko Sugawara; Norihiro Kokudo; Masatoshi Makuuchi
Journal:  Ann Surg       Date:  2009-08       Impact factor: 12.969

10.  Bloodless liver resection using the monopolar floating ball plus ligasure diathermy: preliminary results of 16 liver resections.

Authors:  Yoshihiro Sakamoto; Junji Yamamoto; Norihiro Kokudo; Makoto Seki; Tomoo Kosuge; Toshiharu Yamaguchi; Tetsuichiro Muto; Masatoshi Makuuchi
Journal:  World J Surg       Date:  2004-01-08       Impact factor: 3.352

View more
  3 in total

1.  Impact of energy devices during liver parenchymal transection: a multicenter randomized controlled trial.

Authors:  Naoto Gotohda; Takeharu Yamanaka; Akio Saiura; Katsuhiko Uesaka; Masaji Hashimoto; Masaru Konishi; Kazuaki Shimada
Journal:  World J Surg       Date:  2015-06       Impact factor: 3.352

2.  Spray Diathermy Versus Harmonic Scalpel Technique for Hepatic Parenchymal Transection of Living Donor.

Authors:  Mohamed El Shobary; Tarek Salah; Ayman El Nakeeb; Ahmad M Sultan; Ahmed Elghawalby; Omar Fathy; Mohamed Abdel Wahab; Amro Yassen; Mohamed Elmorshedy; Wagdi F Elkashef; Usama Shiha; Mohamed Elsadany
Journal:  J Gastrointest Surg       Date:  2016-10-31       Impact factor: 3.452

3.  Efficacy of a half-grip technique using a fine tip LigaSure™, Dolphin Tip Sealer/Divider, on liver dissection in swine model.

Authors:  Yoichi Toyama; Seiya Yoshida; Ryota Saito; Ryota Iwase; Koichiro Haruki; Norimitsu Okui; Jun-ichi Shimada; Hiroaki Kitamura; Michinori Matsumoto; Katsuhiko Yanaga
Journal:  BMC Res Notes       Date:  2015-08-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.