Literature DB >> 22544071

Analysis of elemental concentration using ICP-AES and pathogen indicator in drinking water of Qasim Abad, District Rawalpindi, Pakistan.

Shama Sehar1, Iffat Naz, Naeem Ali, Safia Ahmed.   

Abstract

The present study was conducted to investigate drinking water quality (groundwater) from water samples taken from Qasim Abad, a locality of approximately 5,000 population, situated between twin cities Rawalpindi and Islamabad in Pakistan. The main sources of drinking water in this area are water bores which are dug upto the depth of 250-280 ft in almost every house. The study consists of the determination of physico-chemical properties, trace metals, heavy metals, rare earth elements and microbiological quality of drinking water. The data showed the variation of the investigated parameters in samples as follows: pH 6.75 to 8.70, electrical conductivity 540 to 855 μS/cm, total dissolved solids 325.46 to 515.23 ppm and dissolved oxygen 1.50 to 5.64 mg/L which are within the WHO guidelines for drinking water quality. The water samples were analysed for 30 elements (aluminium, iron, magnesium, manganese, silicon, zinc, molybdenum, titanium, chromium, nickel, tungsten, silver, arsenic, boron, barium, beryllium, cadmium, cobalt, copper, gallium, mercury, lanthanum, niobium, neodymium, lead, selenium, samarium, tin, vanadium and zirconium) by using inductively coupled plasma atomic emission spectroscopy. The organic contamination was detected in terms of most probable number (MPN) of faecal coliforms. Overall, elemental levels were lower than the recommended values but three water bores (B-1, B-6, B-7) had higher values of iron (1.6, 2.206, 0.65 ppm), two water bores (B-1, B-6) had higher values of aluminium (0.95, 1.92 ppm), respectively, and molybdenum was higher by 0.01 ppm only in one water bore (B-11). The total number of coliforms present in water samples was found to be within the prescribed limit of the WHO except for 5 out of 11 bore water samples (B-2, B-3, B-4, B-8, B-11), which were found in the range 5-35 MPN/100 mL, a consequence of infiltration of contaminated water (sewage) through cross connection, leakage points and back siphoning.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22544071     DOI: 10.1007/s10661-012-2620-2

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  5 in total

1.  The chromatomembrane method used for sample preparations in the spectrophotometric determination of zinc and copper in pharmaceuticals.

Authors:  Ganden Supriyanto; Jürgen Simon
Journal:  Talanta       Date:  2005-09-26       Impact factor: 6.057

2.  Simultaneous preconcentration and determination of copper, nickel, cobalt and lead ions content by flame atomic absorption spectrometry.

Authors:  Mehrorang Ghaedi; Farshid Ahmadi; Ardeshir Shokrollahi
Journal:  J Hazard Mater       Date:  2006-08-12       Impact factor: 10.588

3.  Incidence of heavy metal contamination in water supplies in northern Mexico.

Authors:  C J Wyatt; C Fimbres; L Romo; R O Méndez; M Grijalva
Journal:  Environ Res       Date:  1998-02       Impact factor: 6.498

4.  Thermal modified Kaolinite as useful material for separation and preconcentration of trace amounts of manganese ions.

Authors:  Darush Afzali; Mohammad Ali Taher; Ali Mostafavi; Sayed Ziae Mohammadi Mobarakeh
Journal:  Talanta       Date:  2005-01-30       Impact factor: 6.057

  5 in total
  2 in total

1.  Groundwater quality assessment in the urban-west region of Zanzibar Island.

Authors:  Abdul A J Mohamed; Ibrahim Abdul Rahman; Lee H Lim
Journal:  Environ Monit Assess       Date:  2014-05-30       Impact factor: 2.513

2.  A nanocomposite consisting of MIL-101(Cr) and functionalized magnetite nanoparticles for extraction and determination of selenium(IV) and selenium(VI).

Authors:  Hossein Kalantari; Mahboobeh Manoochehri
Journal:  Mikrochim Acta       Date:  2018-02-26       Impact factor: 5.833

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.