Literature DB >> 22543199

Planning hybrid intensity modulated radiation therapy for whole-breast irradiation.

Paolo Farace1, Sergio Zucca, Ignazio Solla, Giuseppina Fadda, Silvia Durzu, Sergio Porru, Gianfranco Meleddu, Maria Assunta Deidda, Marco Possanzini, Sivia Orrù, Giancarlo Lay.   

Abstract

PURPOSE: To test tangential and not-tangential hybrid intensity modulated radiation therapy (IMRT) for whole-breast irradiation. METHODS AND MATERIALS: Seventy-eight (36 right-, 42 left-) breast patients were randomly selected. Hybrid IMRT was performed by direct aperture optimization. A semiautomated method for planning hybrid IMRT was implemented using Pinnacle scripts. A plan optimization volume (POV), defined as the portion of the planning target volume covered by the open beams, was used as the target objective during inverse planning. Treatment goals were to prescribe a minimum dose of 47.5 Gy to greater than 90% of the POV and to minimize the POV and/or normal tissue receiving a dose greater than 107%. When treatment goals were not achieved by using a 4-field technique (2 conventional open plus 2 IMRT tangents), a 6-field technique was applied, adding 2 non tangential (anterior-oblique) IMRT beams.
RESULTS: Using scripts, manual procedures were minimized (choice of optimal beam angle, setting monitor units for open tangentials, and POV definition). Treatment goals were achieved by using the 4-field technique in 61 of 78 (78%) patients. The 6-field technique was applied in the remaining 17 of 78 (22%) patients, allowing for significantly better achievement of goals, at the expense of an increase of low-dose (∼5 Gy) distribution in the contralateral tissue, heart, and lungs but with no significant increase of higher doses (∼20 Gy) in heart and lungs. The mean monitor unit contribution to IMRT beams was significantly greater (18.7% vs 9.9%) in the group of patients who required 6-field procedure.
CONCLUSIONS: Because hybrid IMRT can be performed semiautomatically, it can be planned for a large number of patients with little impact on human or departmental resources, promoting it as the standard practice for whole-breast irradiation.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22543199     DOI: 10.1016/j.ijrobp.2012.02.025

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  12 in total

1.  Comparison of conventional and advanced radiotherapy techniques for left-sided breast cancer after breast conserving surgery.

Authors:  Yibo Xie; Daniel Bourgeois; Beibei Guo; Rui Zhang
Journal:  Med Dosim       Date:  2020-07-07       Impact factor: 1.482

2.  Deep inspiration breath-hold (DIBH) radiotherapy in left-sided breast cancer: Dosimetrical comparison and clinical feasibility in 20 patients.

Authors:  Rodrigo Hepp; Mark Ammerpohl; Christina Morgenstern; Lisa Nielinger; Patricia Erichsen; Abdallah Abdallah; Razvan Galalae
Journal:  Strahlenther Onkol       Date:  2015-04-18       Impact factor: 3.621

3.  Hybrid volumetric modulated arc therapy for whole breast irradiation: a dosimetric comparison of different arc designs.

Authors:  Velayudham Ramasubramanian; Karunakaran Balaji; Sitaraman Balaji Subramanian; Krishnamoorthi Sathiya; Moorthi Thirunavukarasu; Chandrasekaran Anu Radha
Journal:  Radiol Med       Date:  2019-01-30       Impact factor: 3.469

4.  Bi-tangential hybrid IMRT for sparing the shoulder in whole breast irradiation.

Authors:  P Farace; M A Deidda; I Iamundo de Cumis; I Iamundo de Curtis; E Deiana; R Farigu; G Lay; S Porru
Journal:  Strahlenther Onkol       Date:  2013-10-10       Impact factor: 3.621

5.  Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities.

Authors:  Yoshiko Doi; Minoru Nakao; Hideharu Miura; Shuichi Ozawa; Masahiro Kenjo; Yasushi Nagata
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

Review 6.  Intensity-modulated radiation therapy for early-stage breast cancer: is it ready for prime time?

Authors:  Tabitha Y Chan; Poh Wee Tan; Johann I Tang
Journal:  Breast Cancer (Dove Med Press)       Date:  2017-03-20

7.  A three-field monoisocentric inverse breast treatment planning technique without half-beam blocking.

Authors:  Tiezhi Zhang; Joshua T Dilworth; Ovidiu Marina; Peter Chen; Lisa Benedetti; Qiang Liu
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

8.  Automated planning of whole breast irradiation using hybrid IMRT improves efficiency and quality.

Authors:  Bingqi Guo; Chirag Shah; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2019-11-19       Impact factor: 2.102

9.  Template-based breast IMRT planning for increased workload efficiency.

Authors:  Sonia Kim Anh Nguyen; Fred Cao; Ramani Ramaseshan; Sarah Kristensen; Krista Kuncewicz; Vicky Huang; Craig Elith; Peter Steiner; Jennifer Hayes; Beverly Lester; Cheryl McGregor; Bilal Shahine; Winkle Kwan
Journal:  Radiat Oncol       Date:  2013-03-20       Impact factor: 3.481

10.  Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index.

Authors:  Jackie Yim; Clare Suttie; Regina Bromley; Marita Morgia; Gillian Lamoury
Journal:  J Med Radiat Sci       Date:  2015-08-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.