Literature DB >> 22541964

Implementation of remote 3-dimensional image guided radiation therapy quality assurance for radiation therapy oncology group clinical trials.

Yunfeng Cui1, James M Galvin, William Parker, Stephen Breen, Fang-Fang Yin, Jing Cai, Lech S Papiez, X Allen Li, Greg Bednarz, Wenzhou Chen, Ying Xiao.   

Abstract

PURPOSE: To report the process and initial experience of remote credentialing of three-dimensional (3D) image guided radiation therapy (IGRT) as part of the quality assurance (QA) of submitted data for Radiation Therapy Oncology Group (RTOG) clinical trials; and to identify major issues resulting from this process and analyze the review results on patient positioning shifts. METHODS AND MATERIALS: Image guided radiation therapy datasets including in-room positioning CT scans and daily shifts applied were submitted through the Image Guided Therapy QA Center from institutions for the IGRT credentialing process, as required by various RTOG trials. A centralized virtual environment is established at the RTOG Core Laboratory, containing analysis tools and database infrastructure for remote review by the Physics Principal Investigators of each protocol. The appropriateness of IGRT technique and volumetric image registration accuracy were evaluated. Registration accuracy was verified by repeat registration with a third-party registration software system. With the accumulated review results, registration differences between those obtained by the Physics Principal Investigators and from the institutions were analyzed for different imaging sites, shift directions, and imaging modalities.
RESULTS: The remote review process was successfully carried out for 87 3D cases (out of 137 total cases, including 2-dimensional and 3D) during 2010. Frequent errors in submitted IGRT data and challenges in the review of image registration for some special cases were identified. Workarounds for these issues were developed. The average differences of registration results between reviewers and institutions ranged between 2 mm and 3 mm. Large discrepancies in the superior-inferior direction were found for megavoltage CT cases, owing to low spatial resolution in this direction for most megavoltage CT cases.
CONCLUSION: This first experience indicated that remote review for 3D IGRT as part of QA for RTOG clinical trials is feasible and effective. The magnitude of registration discrepancy between institution and reviewer was presented, and the major issues were investigated to further improve this remote evaluation process.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22541964     DOI: 10.1016/j.ijrobp.2012.03.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Radiation therapy quality assurance in clinical trials--Global Harmonisation Group.

Authors:  Christos Melidis; Walter R Bosch; Joanna Izewska; Elena Fidarova; Eduardo Zubizarreta; Satoshi Ishikura; David Followill; James Galvin; Ying Xiao; Martin A Ebert; Tomas Kron; Catharine H Clark; Elizabeth A Miles; Edwin G A Aird; Damien C Weber; Kenneth Ulin; Dirk Verellen; Coen W Hurkmans
Journal:  Radiother Oncol       Date:  2014-05-08       Impact factor: 6.280

2.  Credentialing for participation in clinical trials.

Authors:  David S Followill; Marcia Urie; James M Galvin; Kenneth Ulin; Ying Xiao; Thomas J Fitzgerald
Journal:  Front Oncol       Date:  2012-12-26       Impact factor: 6.244

  2 in total