Kinematic adaptations to a variable stiffness shoe: mechanisms for reducing joint loading.

K A Boyer1, P Federolf, C Lin, B M Nigg, T P Andriacchi.   

Abstract

A recently described variable-stiffness shoe has been shown to reduce the adduction moment and pain in patients with medial-compartment knee osteoarthritis. The mechanism associated with how this device modifies overall gait patterns to reduce the adduction moment is not well understood. Yet this information is important for applying load modifying intervention for the treatment of knee osteoarthritis. A principal component analysis (PCA) was used to test the hypothesis that there are differences in the frontal plane kinematics that are correlated with differences in the ground reaction forces (GRFs) and center of pressure (COP) for a variable-stiffness compared to a constant-stiffness control shoe. Eleven healthy adults were tested in a constant-stiffness control shoe and a variable-stiffness shoe while walking at self-selected speeds. The PCA was performed on trial vectors consisting of all kinematic, GRF and COP data. The projection of trial vectors onto the linear combination of four PCs showed there were significant differences between shoes. The interpretation of the PCs indicated an increase in the ankle eversion, knee abduction and adduction, decreases in the hip adduction and pelvic obliquity angles and reduced excursion of both the COP and peak medial-lateral GRFs for the variable-stiffness compared to the control shoe. The variable-stiffness shoe produced a unique dynamic change in the frontal plane motion of the ankle, hip and pelvis that contributed to changes in the GRF and COP and thus reduced the adduction moment at a critical instant during gait suggesting a different mechanism that was seen with fixed interventions (e.g. wedges).
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22541945     DOI: 10.1016/j.jbiomech.2012.04.010

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  What predicts the first peak of the knee adduction moment?

Authors:  Anne Schmitz; Brian Noehren
Journal:  Knee       Date:  2014-07-24       Impact factor: 2.199

2.  Analysis of hip joint loading during walking with different shoe types using instrumented total hip prostheses.

Authors:  Y Palmowski; S Popović; D Kosack; P Damm
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

3.  A novel approach to solve the "missing marker problem" in marker-based motion analysis that exploits the segment coordination patterns in multi-limb motion data.

Authors:  Peter Andreas Federolf
Journal:  PLoS One       Date:  2013-10-30       Impact factor: 3.240

4.  Stiffening the human foot with a biomimetic exotendon.

Authors:  Ryan C Riddick; Dominic J Farris; Nicholas A T Brown; Luke A Kelly
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379

5.  Investigation of the biomechanical effect of variable stiffness shoe on external knee adduction moment in various dynamic exercises.

Authors:  Jee Chin Teoh; Jin Huat Low; Ying Bena Lim; Victor Phyau-Wui Shim; Jaeyoung Park; Seung-Bum Park; Sang Jun Park; Taeyong Lee
Journal:  J Foot Ankle Res       Date:  2013-09-17       Impact factor: 2.303

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.