Literature DB >> 2254053

Effect of suction on specimen size in fine-needle aspiration biopsy.

J Kreula1, P Virkkunen, S Bondestam.   

Abstract

High incidences of unsatisfactory specimens in fine-needle aspiration biopsy for cytology have been reported previously. Inappropriate aspiration techniques may account partly for this. In this study, the effect of suction on specimen size was studied in vitro using an automatic sampler. Bovine liver, testis, and pig's kidney were used as target tissues and biopsies were performed with 18-, 20- and 22-gauge needles. Specimen weight increased rapidly and linearly with suction force (P less than .001), regardless of the target tissue or needle diameter, when standard needle movement was applied. In the absence of needle movement, the suction force, rate of increase of suction, and duration of suction had no effect on the weight of the specimens. Needle movement alone, without suction, also produced meager specimens. Suction alone does not seem to tear fragments off target tissues. Nevertheless, in combination with needle movement, suction force plays an important role in the determination of specimen size.

Entities:  

Mesh:

Year:  1990        PMID: 2254053     DOI: 10.1097/00004424-199011000-00005

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Syringe and needle size, syringe type, vacuum generation, and needle control in aspiration procedures.

Authors:  Luke J Haseler; Randy R Sibbitt; Wilmer L Sibbitt; Adrian A Michael; Charles M Gasparovic; Arthur D Bankhurst
Journal:  Cardiovasc Intervent Radiol       Date:  2010-11-06       Impact factor: 2.740

2.  CT-GUIDED FNAC AND BIOPSY : OUR EXPERIENCE.

Authors:  M N Sree Ram; P Joshi; R Pant; J C Choudhury
Journal:  Med J Armed Forces India       Date:  2017-06-26

3.  New device technologies for subcutaneous fat biopsy.

Authors:  Lawrence G Kettwich; Wilmer L Sibbitt; N Suzanne Emil; Usman Ashraf; Leslie Sanchez-Goettler; Yumna Thariani; Arthur D Bankhurst
Journal:  Amyloid       Date:  2012-03-27       Impact factor: 7.141

4.  The diagnostic quality of needle brain biopsy specimens obtained with different sampling methods - Experimental study.

Authors:  Piotr Trojanowski; Bożena Jarosz; Dariusz Szczepanek
Journal:  Sci Rep       Date:  2019-05-30       Impact factor: 4.379

5.  Ultrasonic actuation of a fine-needle improves biopsy yield.

Authors:  Emanuele Perra; Eetu Lampsijärvi; Gonçalo Barreto; Muhammad Arif; Tuomas Puranen; Edward Hæggström; Kenneth P H Pritzker; Heikki J Nieminen
Journal:  Sci Rep       Date:  2021-04-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.