The effect of a low-carbohydrate/high-monounsaturated fatty acid liquid diet and an isoleucine-containing liquid diet on 24-h glycemic variability in diabetes patients on tube feeding: a comparison by continuous glucose monitoring.

Yutaka Mori1, Teruo Ohta, Masatsugu Shiozaki, Junichi Yokoyama, Kazunori Utsunomiya.   

Abstract

OBJECTIVE: This study compare the effect of various liquid diets on 24-h glycemic variability in diabetes patients on tube feeding. PATIENTS AND METHODS: The study included type 2 diabetes patients in whom percutaneous endoscopic gastrostomy had been performed for dysphagia as a sequela of cerebrovascular disease and who had been put on tube feeding with a standard high-carbohydrate liquid diet (HCD). Once stable glycemic control was achieved, these patients were continuously monitored for glucose levels for 5 days on continuous glucose monitoring. Of the 14 patients included, seven were given HCD on day 1, a low-carbohydrate/high-monounsaturated fatty acid liquid diet (LCD) on Days 2 and 3, and a isoleucine-containing liquid diet (ICD), which is known to promote glycemic uptake by skeletal muscle, thus suppressing increases in glucose levels, on Days 4 and 5, with the remaining seven given the same diets but ICD given on Days 2 and 3 and LCD given on Days 4 and 5. All comparisons were made under the same caloric conditions (caloric intake, 800-1200 kcal/day).
RESULTS: The 24-h mean glucose level was significantly lower with LCD and ICD than with HCD but was also significantly lower with LCD than with ICD. On the other hand, the SD of 288 glucose levels over a 24-h period, 24-h total area for glycemic fluctuations, and mean amplitude of glycemic excursion were significantly lower with LCD than with HCD or ICD, whereas they did not differ significantly between HCD and ICD.
CONCLUSIONS: LCD and ICD led to significant decreases in mean glucose levels, compared with HCD. However, of the diets compared, LCD had the greatest effect on glycemic variability in these patients on tube feeding.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22540521     DOI: 10.1089/dia.2011.0288

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  1 in total

1.  Comparison of morning basal + 1 bolus insulin therapy (insulin glulisine + insulin glargine 300 U/mL vs insulin lispro + insulin glargine biosimilar) using continuous glucose monitoring: A randomized crossover study.

Authors:  Soichi Takeishi; Hiroki Tsuboi; Shodo Takekoshi
Journal:  J Diabetes Investig       Date:  2017-06-10       Impact factor: 4.232

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.