Literature DB >> 22538738

The implantable loop recorder-an important addition to the armentarium in the management of unexplained syncope.

Nesan Shanmugam1, Reginald Liew.   

Abstract

INTRODUCTION: Unexplained syncope is a common condition with a significant impact both on the patient and on healthcare expenditure. Often, the diagnosis is hampered due to the temporary sporadic nature of the symptoms. Conventional monitoring methods have a low yield for identifying an abnormality during a spontaneous event. The implantable loop recorder (ILR), often underutilised, is an important diagnostic device that may fi ll this void in the early assessment of patients presenting with syncope.
MATERIALS AND METHODS: This article begins with 2 case vignettes which highlight the clinical utility of ILRs in making a definitive diagnosis and guiding subsequent management. This is followed by a review of the existing evidence for ILRs, including the recent international guidelines, underpinning the role of ILRs in the present management algorithm of patients presenting with unexplained syncope. The technical aspects and cost implications will also be reviewed.
RESULTS: Present evidence-based international guidelines have recommended the early use of ILRs in the management of patients with unexplained syncope. Furthermore, there may also be an important role for ILR use in patients with presumed epilepsy refractory to treatment and in the neurally mediated syncope cohort with recurrent symptoms. Cost benefit analysis also demonstrates advantages with early ILR use.
CONCLUSION: The early use of ILR in selected patients remains an accurate, cost-effective, high yield tool for diagnosis and management of patients with unexplained syncope. However, its use should not detract from the importance of taking a detailed medical history and physical examination in the initial assessment to facilitate identification of the aetiology and risk stratification of patients.

Entities:  

Mesh:

Year:  2012        PMID: 22538738

Source DB:  PubMed          Journal:  Ann Acad Med Singapore        ISSN: 0304-4602            Impact factor:   2.473


  4 in total

1.  Editorial: Frailty, Comorbidity, and COPD.

Authors:  E Charbek; J R Espiritu; R Nayak; J E Morley
Journal:  J Nutr Health Aging       Date:  2018       Impact factor: 4.075

2.  F3ALLS Approach to Preventing Falls.

Authors:  J E Morley
Journal:  J Nutr Health Aging       Date:  2018       Impact factor: 4.075

3.  Catecholaminergic Polymorphic Ventricular Tachycardia: A Rare Cause of Cardiac Arrest Following Blunt Chest Trauma.

Authors:  Isa Ozyilmaz; Sinem Ozyilmaz; Yakup Ergul; Celal Akdeniz; Volkan Tuzcu
Journal:  Acta Cardiol Sin       Date:  2015-07       Impact factor: 2.672

4.  Value of Implantable Loop Recorders in Monitoring Efficacy of Radiofrequency Catheter Ablation in Atrial Fibrillation.

Authors:  Ping Yang; Lijin Pu; Liuqing Yang; Fang Li; Zhiling Luo; Tao Guo; Baotong Hua; Shumin Li
Journal:  Med Sci Monit       Date:  2016-08-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.