Minimally invasive enzyme microprobes: an alternative approach for continuous glucose monitoring.

Anna Radomska Bothelo Moniz, Kostis Michelakis, Jakub Trzebinski, Sanjiv Sharma, Desmond G Johnston, Nick Oliver, Anthony Cass.   

Abstract

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22538163      PMCID: PMC3380796          DOI: 10.1177/193229681200600239

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


× No keyword cloud information.
  4 in total

1.  In vitro characterization of the invasiveness of polymer microneedle against skin.

Authors:  Young-Wook Noh; Tae-Hun Kim; Jong-Suep Baek; Hyoun-Hyang Park; Seung S Lee; Manhee Han; Sang-Chul Shin; Cheong-Weon Cho
Journal:  Int J Pharm       Date:  2010-07-07       Impact factor: 5.875

Review 2.  Glucose sensors: a review of current and emerging technology.

Authors:  N S Oliver; C Toumazou; A E G Cass; D G Johnston
Journal:  Diabet Med       Date:  2009-03       Impact factor: 4.359

3.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

4.  The effect of continuous glucose monitoring in well-controlled type 1 diabetes.

Authors:  Roy W Beck; Irl B Hirsch; Lori Laffel; William V Tamborlane; Bruce W Bode; Bruce Buckingham; Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart A Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  Diabetes Care       Date:  2009-05-08       Impact factor: 19.112

  4 in total
  5 in total

1.  Towards a minimally invasive device for beta-lactam monitoring in humans.

Authors:  Timothy Miles Rawson; Sanjiv Sharma; Pantelis Georgiou; Alison Holmes; Anthony Cass; Danny O'Hare
Journal:  Electrochem commun       Date:  2017-09       Impact factor: 4.724

2.  Hydrogel-Forming Microneedle Arrays Allow Detection of Drugs and Glucose In Vivo: Potential for Use in Diagnosis and Therapeutic Drug Monitoring.

Authors:  Ester Caffarel-Salvador; Aaron J Brady; Eyman Eltayib; Teng Meng; Ana Alonso-Vicente; Patricia Gonzalez-Vazquez; Barbara M Torrisi; Eva Maria Vicente-Perez; Karen Mooney; David S Jones; Steven E J Bell; Colin P McCoy; Helen O McCarthy; James C McElnay; Ryan F Donnelly
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

Review 3.  Microneedle-based devices for point-of-care infectious disease diagnostics.

Authors:  Rachael V Dixon; Eldhose Skaria; Wing Man Lau; Philip Manning; Mark A Birch-Machin; S Moein Moghimi; Keng Wooi Ng
Journal:  Acta Pharm Sin B       Date:  2021-02-16       Impact factor: 11.413

4.  Evaluation of a minimally invasive glucose biosensor for continuous tissue monitoring.

Authors:  Sanjiv Sharma; Zhenyi Huang; Michelle Rogers; Martyn Boutelle; Anthony E G Cass
Journal:  Anal Bioanal Chem       Date:  2016-10-15       Impact factor: 4.142

Review 5.  Delivering precision antimicrobial therapy through closed-loop control systems.

Authors:  T M Rawson; D O'Hare; P Herrero; S Sharma; L S P Moore; E de Barra; J A Roberts; A C Gordon; W Hope; P Georgiou; A E G Cass; A H Holmes
Journal:  J Antimicrob Chemother       Date:  2018-04-01       Impact factor: 5.790

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.