Literature DB >> 22537423

Bleeding complications of native kidney biopsy: a systematic review and meta-analysis.

Kristin M Corapi1, Joline L T Chen, Ethan M Balk, Craig E Gordon.   

Abstract

BACKGROUND: Kidney biopsy provides important information for nephrologists, but the risk of complications has not been systematically described. STUDY
DESIGN: Meta-analysis of randomized controlled trials and prospective or retrospective observational studies. SETTING & POPULATION: Adults undergoing native kidney biopsy in an inpatient or outpatient setting. SELECTION CRITERIA FOR STUDIES: MEDLINE indexed studies from January 1980 through June 2011; sample size of 50 or more. INTERVENTION: Native kidney biopsy with automated biopsy device and real-time ultrasonographic guidance. OUTCOMES: Macroscopic hematuria and erythrocyte transfusion rates and factors associated with these outcomes.
RESULTS: 34 studies of 9,474 biopsies met inclusion criteria. The rate of macroscopic hematuria was 3.5% (95% CI, 2.2%-5.1%), and erythrocyte transfusion was 0.9% (95% CI, 0.4%-1.5%). Significantly higher rates of transfusion were seen with the following: 14-gauge compared with smaller needles (2.1% vs 0.5%; P = 0.009), studies with mean serum creatinine level ≥2.0 mg/dL (2.1% vs 0.4%; P = 0.02), ≥50% women (1.9% vs 0.6%; P = 0.03), and ≥10% of biopsies for acute kidney injury (1.1% vs 0.04%; P < 0.001). Higher transfusion rates also were observed in studies with a mean age of 40 years or older (1.0% vs 0.2%; P = 0.2) and mean systolic blood pressure ≥130 mm Hg (1.4% vs 0.1%; P = 0.09). Similar relationships were noted for the macroscopic hematuria rate with the same predictors, but none was statistically significant. LIMITATIONS: Publication bias, few randomized controlled trials, and missing data.
CONCLUSIONS: Native kidney biopsy using automated biopsy devices and real-time ultrasonography is associated with a relatively small risk of macroscopic hematuria and erythrocyte transfusion requirement. Using smaller gauge needles may lower complication rates. Patient selection may affect outcome because studies with higher serum creatinine levels, more women, and higher rates of acute kidney injury had higher complication rates. Future studies should further evaluate risk factors for complications.
Copyright © 2012 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22537423     DOI: 10.1053/j.ajkd.2012.02.330

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  105 in total

1.  Positive trends in paediatric renal biopsy service provision in the UK: a national survey and re-audit of paediatric renal biopsy practice.

Authors:  Asheeta Gupta; Joanna Campion-Smith; Wesley Hayes; Jane E Deal; Rodney D Gilbert; Carole Inward; Brian A Judd; Rajesh G Krishnan; Stephen D Marks; Catherine O'Brien; Mohan Shenoy; Manish D Sinha; Yincent Tse; Kay Tyerman; Meeta Mallik; Farida Hussain
Journal:  Pediatr Nephrol       Date:  2015-11-02       Impact factor: 3.714

Review 2.  The Native Kidney Biopsy: Update and Evidence for Best Practice.

Authors:  Jonathan J Hogan; Michaela Mocanu; Jeffrey S Berns
Journal:  Clin J Am Soc Nephrol       Date:  2015-09-02       Impact factor: 8.237

3.  Evaluating renal biopsy-associated hemorrhage complications by the equation and providing an early intervention: a single-center experience.

Authors:  Chao Wang; Yang Yang; Liping Jin; Ying Zhang; Guanglei Chen; Zhuliang Zhou; Minghui Song; Qingman Gao; Changchun Li; Tao Pan; Fagui He; Lu Ma
Journal:  J Nephrol       Date:  2015-04-15       Impact factor: 3.902

Review 4.  Complications of Percutaneous Renal Biopsy.

Authors:  Kenaz Bakdash; Kristofer M Schramm; Aparna Annam; Matthew Brown; Kimi Kondo; Jonathan D Lindquist
Journal:  Semin Intervent Radiol       Date:  2019-05-22       Impact factor: 1.513

5.  A Pregnant Woman with Lupus and Nephrotic-Range Proteinuria.

Authors:  Andrew S Bomback
Journal:  Clin J Am Soc Nephrol       Date:  2017-04-04       Impact factor: 8.237

6.  Kidney Biopsy in Hospitalized Patients with Acute Kidney Disease: Is There an Increased Risk?

Authors:  Steven Darrow Weisbord
Journal:  Clin J Am Soc Nephrol       Date:  2018-10-22       Impact factor: 8.237

7.  Preeclampsia before 20 weeks of gestation: a case report and review of the literature.

Authors:  Mari Tanaka; Yasushi Tsujimoto; Kimihiko Goto; Kana Kumahara; Saeko Onishi; Sachio Iwanari; Daiki Fumihara; Syo Miki; Masaki Ikeda; Kanae Sato; Hiroshi Sato; Masaya Hirose; Hiroya Takeoka
Journal:  CEN Case Rep       Date:  2014-08-09

8.  Major Bleeding and Risk of Death after Percutaneous Native Kidney Biopsies: A French Nationwide Cohort Study.

Authors:  Jean-Michel Halimi; Philippe Gatault; Hélène Longuet; Christelle Barbet; Arnaud Bisson; Bénédicte Sautenet; Julien Herbert; Matthias Buchler; Leslie Grammatico-Guillon; Laurent Fauchier
Journal:  Clin J Am Soc Nephrol       Date:  2020-10-15       Impact factor: 8.237

9.  Complications of automated spring fired biopsy gun technique. A retrospective analysis of 230 cases.

Authors:  M Lubomirova; T Tzocheva; M Hristova; B Bogov
Journal:  Hippokratia       Date:  2014-01       Impact factor: 0.471

10.  Magnetic Resonance Elastography to Assess Fibrosis in Kidney Allografts.

Authors:  Anish Kirpalani; Eyesha Hashim; General Leung; Jin K Kim; Adriana Krizova; Serge Jothy; Maya Deeb; Nan N Jiang; Lauren Glick; Gevork Mnatzakanian; Darren A Yuen
Journal:  Clin J Am Soc Nephrol       Date:  2017-08-30       Impact factor: 8.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.