Anna Chi Shan Kam1. 1. Department of Otorhinolaryngology, Head and Neck Surgery, Chinese University of Hong Kong, Shatin, Hong Kong. annakam@ent.cuhk.edu.hk
Abstract
OBJECTIVE: To adapt the Satisfaction with Amplification in Daily Life questionnaire into Chinese (the SADL-CH questionnaire) and investigate hearing-aid satisfaction in a group of adult Hong Kong Chinese fitted with free hearing aids. DESIGN: Cross-sectional survey. STUDY SAMPLE: One hundred and twenty-five experienced hearing-aid users. METHODS: The subjects completed a history form seeking demographic data and a questionnaire combining the SADL-CH instrument with questions seeking subjects' subjective ratings of satisfaction with some hearing-aid features and overall satisfaction with their hearing aid. RESULTS: The SADL-CH questionnaire had a good internal consistency reliability estimate (α = 0.79) comparable to that of the original version. SADL-CH scores were observed to have significant correlations with other satisfaction ratings on some hearing-aid features and the overall satisfaction measure. A high degree of test-retest reliability (intraclass correlation coefficient = 0.79) was observed. Confirmatory factor analysis revealed that the SADL-CH questionnaire had a four-factor structure. Interim norms were derived for the SADL-CH questionnaire. The level of hearing-aid satisfaction in Chinese adults was generally lower than that reported in studies conducted among Western populations. CONCLUSION: The SADL-CH questionnaire is a reliable and valid instrument for measuring hearing-aid satisfaction.
OBJECTIVE: To adapt the Satisfaction with Amplification in Daily Life questionnaire into Chinese (the SADL-CH questionnaire) and investigate hearing-aid satisfaction in a group of adult Hong Kong Chinese fitted with free hearing aids. DESIGN: Cross-sectional survey. STUDY SAMPLE: One hundred and twenty-five experienced hearing-aid users. METHODS: The subjects completed a history form seeking demographic data and a questionnaire combining the SADL-CH instrument with questions seeking subjects' subjective ratings of satisfaction with some hearing-aid features and overall satisfaction with their hearing aid. RESULTS: The SADL-CH questionnaire had a good internal consistency reliability estimate (α = 0.79) comparable to that of the original version. SADL-CH scores were observed to have significant correlations with other satisfaction ratings on some hearing-aid features and the overall satisfaction measure. A high degree of test-retest reliability (intraclass correlation coefficient = 0.79) was observed. Confirmatory factor analysis revealed that the SADL-CH questionnaire had a four-factor structure. Interim norms were derived for the SADL-CH questionnaire. The level of hearing-aid satisfaction in Chinese adults was generally lower than that reported in studies conducted among Western populations. CONCLUSION: The SADL-CH questionnaire is a reliable and valid instrument for measuring hearing-aid satisfaction.
Authors: Joannie Ka Yin Yu; Lena Lai Nar Wong; Willis Sung Shan Tsang; Michael Chi Fai Tong Journal: Biomed Res Int Date: 2014-06-02 Impact factor: 3.411