Literature DB >> 22535724

Preliminary study on the diagnostic value of acoustic radiation force impulse technology for differentiating between benign and malignant thyroid nodules.

Jiying Gu1, Lianfang Du, Min Bai, Huili Chen, Xiao Jia, Jing Zhao, Xuemei Zhang.   

Abstract

OBJECTIVES: This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions.
METHODS: Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the χ(2) test were used to compare the elastic parameters.
RESULTS: Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values ± SD of 2.034 ± 0.484, 1.835 ± 0.364, 2.293 ± 0.787, and 3.941 ± 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001).
CONCLUSIONS: Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.

Entities:  

Mesh:

Year:  2012        PMID: 22535724     DOI: 10.7863/jum.2012.31.5.763

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  21 in total

1.  Acoustic radiation force impulse induced strain elastography and point shear wave elastography for evaluation of thyroid nodules.

Authors:  Xian Huang; Le-Hang Guo; Hui-Xiong Xu; Xue-Hao Gong; Bo-Ji Liu; Jun-Mei Xu; Yi-Feng Zhang; Xiao-Long Li; Dan-Dan Li; Shen Qu; Lin Fang
Journal:  Int J Clin Exp Med       Date:  2015-07-15

2.  Prediction of cervical lymph node metastasis in patients with papillary thyroid cancer using combined conventional ultrasound, strain elastography, and acoustic radiation force impulse (ARFI) elastography.

Authors:  Jun-Mei Xu; Xiao-Hong Xu; Hui-Xiong Xu; Yi-Feng Zhang; Le-Hang Guo; Lin-Na Liu; Chang Liu; Xiao-Wan Bo; Shen Qu; Mingzhao Xing; Xiao-Long Li
Journal:  Eur Radiol       Date:  2015-11-11       Impact factor: 5.315

3.  Acoustic radiation force impulse (ARFI) elastography for detection of renal damage in children.

Authors:  Cemil Göya; Cihad Hamidi; Aydın Ece; Mehmet Hanifi Okur; Bekir Taşdemir; Mehmet Güli Çetinçakmak; Salih Hattapoğlu; Memik Teke; Cahit Şahin
Journal:  Pediatr Radiol       Date:  2014-07-27

4.  Acoustic Radiation Force Impulse (ARFI) imaging for the distinction between benign and malignant thyroid nodules.

Authors:  Cihad Hamidi; Cemil Göya; Salih Hattapoğlu; Ömer Uslukaya; Memik Teke; Mehmet Sedat Durmaz; Mehmet Sıddık Yavuz; Arif Hamidi; Güven Tekbaş
Journal:  Radiol Med       Date:  2015-01-16       Impact factor: 3.469

5.  Elastography of Thyroid Masses.

Authors:  Manjiri K Dighe
Journal:  Ultrasound Clin       Date:  2014-01

6.  Comb-push ultrasound shear elastography (CUSE) for evaluation of thyroid nodules: preliminary in vivo results.

Authors:  Mohammad Mehrmohammadi; Pengfei Song; Duane D Meixner; Robert T Fazzio; Shigao Chen; James F Greenleaf; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Trans Med Imaging       Date:  2014-08-08       Impact factor: 10.048

Review 7.  The role of elastography in evaluating thyroid nodules: a literature review and meta-analysis.

Authors:  Vik Veer; Srikanth Puttagunta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-07-06       Impact factor: 2.503

Review 8.  Diagnostic performance of shear wave elastography in the identification of malignant thyroid nodules: a meta-analysis.

Authors:  Peiliang Lin; Minqi Chen; Baoxian Liu; Siwen Wang; Xiaoxi Li
Journal:  Eur Radiol       Date:  2014-08-12       Impact factor: 5.315

9.  Elasticity of healthy Achilles tendon decreases with the increase of age as determined by acoustic radiation force impulse imaging.

Authors:  Zhengmin Ruan; Bin Zhao; Hengtao Qi; Yuan Zhang; Feixue Zhang; Mei Wu; Guangrui Shao
Journal:  Int J Clin Exp Med       Date:  2015-01-15

10.  Prospective evaluation of acoustic radiation force impulse technology in the differentiation of thyroid nodules: accuracy and interobserver variability assessment.

Authors:  Hektor Grazhdani; Vito Cantisani; Pietro Lodise; Giorgio Di Rocco; Maria Cristina Proietto; Eloisa Fioravanti; Antonello Rubini; Adriano Redler
Journal:  J Ultrasound       Date:  2014-01-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.