Literature DB >> 22535568

Whole breast irradiation for small-sized breasts after conserving surgery: is the field-in-field technique optimal?

Dae Sik Yang1, Jung Ae Lee, Won Sup Yoon, Se Young Chung, Suk Lee, Chul Yong Kim, Young Je Park, Gil Soo Son.   

Abstract

BACKGROUND: To determine the optimal whole breast irradiation technique in patients with small-sized breasts, tangential and field-in-field IMRT (FIF) techniques were compared.
METHODS: Sixteen patients with ≤3 cm breast height and ≤350 cc volume were included. Seven patients had 4D CTs performed. The planning target volumes (PTV), editing 5 and 2 mm from the surface on the whole breast, were delineated and called PTV(5) and PTV(2), respectively. Dose-volume histograms of tangential techniques with open beam (OT) and wedge filter (WT), conventional FIF (cFIF), and modified FIF (mFIF) blocking out the lung were produced. Various dose-volume parameters, the dose heterogeneity index (DHtrI), dose homogeneity index (DHmI), and PTV dose improvement (PDI) were calculated.
RESULTS: OT compared with WT showed a significantly favorable V 90 of the heart and lung, and PTV(5)-dose distribution. Comparing OT and cFIF, OT showed significant improvement in the V 95 of PTV(2), whereas cFIF showed significant improvement in the V 95, DHtrI, DHmI, and PDI of the PTV(5). In comparing cFIF and mFIF, mFIF showed improved dose distributions of the heart and lung, while cFIF presented the better V 95, DHtrI, DHmI, and PDI of the PTV(5). Respiratory influences on the absolute dose were mostly within 1 %. The ratio of free breathing and each respiratory phase was similar among OT, cFIF, and mFIF.
CONCLUSIONS: cFIF has favorable dose conformity and is suggested to be an optimal method for small-sized breasts. However, OT for dose coverage close to the skin and mFIF for normal tissue may also be potential alternatives. Respiratory effects are minimal.

Entities:  

Mesh:

Year:  2012        PMID: 22535568     DOI: 10.1007/s12282-012-0365-y

Source DB:  PubMed          Journal:  Breast Cancer        ISSN: 1340-6868            Impact factor:   4.239


  7 in total

1.  Usefulness of the dual energy field-in-field technique in breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Yuichi Kajiura; Masashi Kitahara; Katsuya Matsuyama; Masaya Kawaguchi; Takahiro Yamaguchi; Sunaho Okada; Masayuki Kanematsu
Journal:  Radiol Med       Date:  2015-12-11       Impact factor: 3.469

2.  Letter to the editor concerning Tsuchiya K et al. "Dosimetric comparison between intensity-modulated radiotherapy and standard wedged tangential technique for whole-breast radiotherapy in Asian women with relatively small breast volumes".

Authors:  Maria Grazia Ruo Redda; Silvia Maria Anglesio; Simona Allis; Roberta Verna; Andrea Girardi; Lavinia Bianco; Edoardo Trevisiol; Alessia Reali
Journal:  Radiol Phys Technol       Date:  2013-11-29

3.  Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation.

Authors:  D S Yang; W S Yoon; S Y Chung; J A Lee; S Lee; Y J Park; C Y Kim; G S Son
Journal:  Strahlenther Onkol       Date:  2013-02-28       Impact factor: 3.621

4.  New field-in-field with two reference points method for whole breast radiotherapy: Dosimetric analysis and radiation-induced skin toxicities assessment.

Authors:  Nouha Tekiki; Masahiro Kuroda; Hinata Ishizaka; Abdullah Khasawneh; Majd Barham; Kentaro Hamada; Kohei Konishi; Kohei Sugimoto; Kuniaki Katsui; Soichi Sugiyama; Kenta Watanabe; Kotaro Yoshio; Norihisa Katayama; Takeshi Ogata; Hiroki Ihara; Susumu Kanazawa; Junichi Asaumi
Journal:  Mol Clin Oncol       Date:  2021-07-21

5.  Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Shinya Hayashi; Yuichi Kajiura; Masashi Kitahara; Katsuya Matsuyama; Masayuki Kanematsu; Hiroaki Hoshi
Journal:  Nagoya J Med Sci       Date:  2015-08       Impact factor: 1.131

6.  Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges.

Authors:  Hidekazu Tanaka; Shinya Hayashi; Kazuhiro Ohtakara; Hiroaki Hoshi
Journal:  Radiol Oncol       Date:  2014-01-22       Impact factor: 2.991

7.  Determination of the optimal method for the field-in-field technique in breast tangential radiotherapy.

Authors:  Hidekazu Tanaka; Shinya Hayashi; Hiroaki Hoshi
Journal:  J Radiat Res       Date:  2014-02-16       Impact factor: 2.724

  7 in total