Literature DB >> 22535188

Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation.

Tobias Koppara1, Michael Joner, Gerd Bayer, Kristin Steigerwald, Tobias Diener, Eric Wittchow.   

Abstract

Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher™) at 28, 90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher™ at 28 days, with significant greater reductions at 90 and 180 days (1.7 ± 0.7 mm² vs. 3.1 ± 1.5 mm², p=0.03 and 1.8 ± 1.2 mm² vs. 3.0 ± 1.5 mm², p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher™ may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22535188     DOI: 10.1160/TH12-01-0043

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  7 in total

1.  Assessment of the healing process after percutaneous implantation of a cardiovascular device: a systematic review.

Authors:  Elodie Perdreau; Zakaria Jalal; Richard D Walton; Jérôme Naulin; Julie Magat; Bruno Quesson; Hubert Cochet; Olivier Bernus; Jean-Benoît Thambo
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-19       Impact factor: 2.357

2.  Late neointimal volume reduction is observed following biodegradable polymer-based drug eluting stent in porcine model.

Authors:  Takeshi Ijichi; Gaku Nakazawa; Sho Torii; Hirofumi Nagamatsu; Ayako Yoshikawa; Shintaro Nakamura; Junko Souba; Atsushi Isobe; Hitomi Hagiwara; Yuji Ikari
Journal:  Int J Cardiol Heart Vasc       Date:  2021-05-11

3.  Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents.

Authors:  Abhilash Akinapelli; Jack P Chen; Kristine Roy; Joseph Donnelly; Keith Dawkins; Barbara Huibregtse; Dongming Hou
Journal:  Curr Cardiol Rev       Date:  2017

4.  Three-year clinical outcome of biodegradable hybrid polymer Orsiro sirolimus-eluting stent and the durable biocompatible polymer Resolute Integrity zotarolimus-eluting stent: A randomized controlled trial.

Authors:  Soo-Hyun Kim; Si-Hyuck Kang; Joo Myung Lee; Woo-Young Chung; Jin Joo Park; Chang-Hwan Yoon; Jung-Won Suh; Young-Seok Cho; Joon-Hyung Doh; Jin Man Cho; Jang-Whan Bae; Tae-Jin Youn; In-Ho Chae
Journal:  Catheter Cardiovasc Interv       Date:  2019-12-20       Impact factor: 2.692

5.  Safety of 3-Month Dual Antiplatelet Therapy After Implantation of Ultrathin Sirolimus-Eluting Stents With Biodegradable Polymer (Orsiro): Results From the SMART-CHOICE Trial.

Authors:  Kyeong Ho Yun; Seung-Yul Lee; Byung Ryul Cho; Woo Jin Jang; Young Bin Song; Ju-Hyeon Oh; Woo Jung Chun; Yong Hwan Park; Eul-Soon Im; Jin-Ok Jeong; Seok Kyu Oh; Deok-Kyu Cho; Jong-Young Lee; Young-Youp Koh; Jang-Whan Bae; Jae Woong Choi; Wang Soo Lee; Hyuck Jun Yoon; Seung Uk Lee; Jang Hyun Cho; Woong Gil Choi; Seung-Woon Rha; Joo Myung Lee; Taek Kyu Park; Jeong Hoon Yang; Jin-Ho Choi; Seung-Hyuck Choi; Sang Hoon Lee; Hyeon-Cheol Gwon; Joo-Yong Hahn
Journal:  J Am Heart Assoc       Date:  2020-12-21       Impact factor: 5.501

6.  Comparison of 9-Month Angiographic Follow-Up and Long-Term Clinical Outcomes of Biodegradable Polymer Drug-Eluting Stents and Second-Generation Durable Polymer Drug-Eluting Stents in Patients Undergoing Single Coronary Artery Stenting.

Authors:  Ming-Lung Tsai; Ming-Jer Hsieh; Chun-Chi Chen; Shang-Hung Chang; Chao-Yung Wang; Dong-Yi Chen; Chia-Hung Yang; Jih-Kai Yeh; Ming-Yun Ho; I-Chang Hsieh
Journal:  Acta Cardiol Sin       Date:  2020-03       Impact factor: 2.672

7.  Procedural advantages of a novel coronary stent design with ultra-thin struts and bioabsorbable abluminal polymer coating in an all-comers registry.

Authors:  Haitham Abu Sharar; Bruna Gomes; Emmanuel Chorianopoulos; Ziya Kaya; Christian A Gleissner; Hugo A Katus; Raffi Bekeredjian
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-09-21       Impact factor: 1.426

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.