Literature DB >> 22534043

Does left ventricular size impact on intrinsic right ventricular function in hypoplastic left heart syndrome?

Jana Schlangen1, Gunther Fischer, Paul Steendijk, Colin Petko, Jens Scheewe, Christopher Hart, Jan H Hansen, Frederick Ahrend, Carsten Rickers, Hans-Heiner Kramer, Anselm Uebing.   

Abstract

BACKGROUND: The size of the remnant left ventricle (LV) may influence right ventricular function and thus long-term outcome in palliated hypoplastic left heart syndrome (HLHS). We therefore sought to assess the impact of the size of the hypoplastic LV on intrinsic RV function in HLHS patients after Fontan surgery.
METHODS: Fifty-seven HLHS patients were studied 2.5 (range: 0.8-12.6) years after Fontan-type palliation with the pressure-volume conductance system. The patient cohort was divided into two groups according to the median LV area index (group 1: LV area index ≤ 1.33 cm(2)/m(2), n=29; group 2: LV area index>1.33 cm(2)/m(2), n=28).
RESULTS: The slopes of the end systolic elastance (Ees) and the preload recruitable stroke work relation (Mw) were not different between group 1 and 2 (Ees: 2.70 ± 1.92 vs. 3.68 ± 2.68 mmHg/ml; Mw: 52.75 ± 14.98 vs. 51.09 ± 16.63 mmHg x ml; P=NS for all). Furthermore, the systolic responses to dobutamine were not statistically different between groups. However, the slope of the end diastolic stiffness (Eed) was higher in group 2 and catecholaminergic stimulation resulted in a decrease in Eed in group 2 (group 1: 0.40 ± 0.26 vs. 0.52 ± 0.45; group 2: 0.68 ± 0.44 vs. 0.47 ± 0.38 mmHg/ml, P<0.01). Furthermore Eed was lowest in patients with mitral atresia/aortic atresia, the anatomic subgroup with the smallest LV remnant.
CONCLUSIONS: Intrinsic systolic RV function is not affected by the size of the hypoplastic LV in survivors of surgical palliation of HLHS. Diastolic stiffness, however, was higher in patients with a larger LV remnant.
Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Hypoplastic left heart syndrome; Left ventricular size; Right ventricular function

Mesh:

Year:  2012        PMID: 22534043     DOI: 10.1016/j.ijcard.2012.03.183

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  7 in total

1.  The Impact of the Left Ventricle on Right Ventricular Function and Clinical Outcomes in Infants with Single-Right Ventricle Anomalies up to 14 Months of Age.

Authors:  Meryl S Cohen; Nicholas Dagincourt; Victor Zak; Jeanne Marie Baffa; Peter Bartz; Andreea Dragulescu; Gul Dudlani; Heather Henderson; Catherine D Krawczeski; Wyman W Lai; Jami C Levine; Alan B Lewis; Rachel T McCandless; Richard G Ohye; Sonal T Owens; Steven M Schwartz; Timothy C Slesnick; Carolyn L Taylor; Peter C Frommelt
Journal:  J Am Soc Echocardiogr       Date:  2018-07-03       Impact factor: 5.251

2.  Ventricular pressure-volume loops obtained by 3D real-time echocardiography and mini pressure wire-a feasibility study.

Authors:  Ulrike Herberg; Eva Gatzweiler; Thomas Breuer; Johannes Breuer
Journal:  Clin Res Cardiol       Date:  2013-02-09       Impact factor: 5.460

3.  Negative Impact of the Left Ventricular Remnant Morphology on Systemic Right Ventricular Myocardial Deformation in Hypoplastic Left Heart Syndrome.

Authors:  Alan P Wang; Angela M Kelle; Meredith Hyun; Chelsea L Reece; Phillip M Young; Patrick W O'Leary; M Yasir Qureshi
Journal:  Pediatr Cardiol       Date:  2020-10-26       Impact factor: 1.655

4.  3D Real-Time Echocardiography Combined with Mini Pressure Wire Generate Reliable Pressure-Volume Loops in Small Hearts.

Authors:  Ulrike Herberg; Katharina Linden; Oliver Dewald; Eva Gatzweiler; Matthias Seehase; Georg Daniel Duerr; Jonas Dörner; Stephanie Kleppe; Dennis Ladage; Johannes Breuer
Journal:  PLoS One       Date:  2016-10-24       Impact factor: 3.240

5.  Assessment of pressure-volume relations in univentricular hearts: Comparison of obtainment by real-time 3D echocardiography and mini pressure-wire with conductance technology.

Authors:  Katharina Linden; Christian Winkler; Johannes Breuer; Ulrike Herberg
Journal:  PLoS One       Date:  2021-02-01       Impact factor: 3.240

6.  Impact of Left Ventricular Morphology on Adverse Outcomes Following Stage 1 Palliation for Hypoplastic Left Heart Syndrome: 20 Years of National Data From Sweden.

Authors:  Katrin Fricke; Mats Mellander; Katarina Hanséus; Phan-Kiet Tran; Mats Synnergren; Jens Johansson Ramgren; Annika Rydberg; Jan Sunnegårdh; Magnus Dalén; Gunnar Sjöberg; Constance G Weismann; Petru Liuba
Journal:  J Am Heart Assoc       Date:  2022-03-29       Impact factor: 6.106

7.  Serial Assessment of Right Ventricular Deformation in Patients With Hypoplastic Left Heart Syndrome: A Cardiovascular Magnetic Resonance Feature Tracking Study.

Authors:  Luca Mitch Kanngiesser; Sandra Freitag-Wolf; Simona Boroni Grazioli; Dominik Daniel Gabbert; Jan Hinnerk Hansen; Anselm Sebastian Uebing; Inga Voges
Journal:  J Am Heart Assoc       Date:  2022-04-27       Impact factor: 6.106

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.