Literature DB >> 22532942

Machined and sandblasted human dental implants retrieved after 5 years: a histologic and histomorphometric analysis of three cases.

Giovanna Iezzi1, Giovanni Vantaggiato, Jamil A Shibli, Elisabetta Fiera, Antonello Falco, Adriano Piattelli, Vittoria Perrotti.   

Abstract

OBJECTIVE: Human retrieved implants with an intact bone-implant interface play a pivotal role in validating data obtained from in vitro studies and animal experiments. This study presents a histologic and histomorphometric analysis of peri-implant tissue reactions and of the bone-titanium interface in three machined and sandblasted dental implants retrieved after a 5-year loading period. METHOD AND MATERIALS: Three implants, with an intact bone-implant interface, were found in the Archives of the Implant Retrieval Center of the Dental School of the University of Chieti-Pescara, Chieti, Italy. The three implants had been used in a two-stage submerged procedure and loaded as part of a small prosthetic restoration. One implant had been retrieved because of an abutment fracture, while there was a fracture of the connecting screw in the other two. One implant was in the maxilla (sandblasted surface), and two were in the mandible (one with a machined surface and the other with a sandblasted surface). All implants had been processed for histology.
RESULTS: All three implants presented mature, compact, lamellar bone at the interface. Many remodeling areas were present in the peri-implant bone, especially inside the implant threads. The bone was always in close contact with the implant surface. The bone-implant contact percentage of the machined implant was 92.7%, while the two sandblasted implants showed bone-implant contact percentages of 85.9% and 76.6%.
CONCLUSION: The present histologic results confirmed that these implants with different surfaces maintained a good level of osseointegration over a 5-year loading period, with continuous remodeling at the interface, and showed high bone-implant contact percentages.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22532942

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  2 in total

1.  Sandblasting reduces dental implant failure rate but not marginal bone level loss: A systematic review and meta-analysis.

Authors:  László Márk Czumbel; Beáta Kerémi; Noémi Gede; Alexandra Mikó; Barbara Tóth; Dezső Csupor; Andrea Szabó; Sándor Farkasdi; Gábor Gerber; Márta Balaskó; Erika Pétervári; Róbert Sepp; Péter Hegyi; Gábor Varga
Journal:  PLoS One       Date:  2019-05-03       Impact factor: 3.240

2.  Histological characteristics of advanced peri-implantitis bone defects in humans.

Authors:  Maria Elisa Galárraga-Vinueza; Stefan Tangl; Marco Bianchini; Ricardo Magini; Karina Obreja; Reinhard Gruber; Frank Schwarz
Journal:  Int J Implant Dent       Date:  2020-03-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.