Literature DB >> 22531225

Electrical impedance tomography system based on active electrodes.

Pascal Olivier Gaggero1, Andy Adler, Josef Brunner, Peter Seitz.   

Abstract

Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, and (2) EIT electrodes are difficult and time consuming to place on patients. This paper presents the design and initial tests of an active electrode-based system to address these difficulties. Our active electrode EIT system incorporates an active electrode belt, a central voltage-driven current source, central analog to digital converters and digital to analog converters, a central FPGA-based demodulator and controller. The electrode belt is designed incorporating 32 active electrodes, each of which contains the electronic amplifiers, switches and associated logic. Tests show stable device performance with a convenient ease of use and good imaging ability in volunteer tests.

Entities:  

Mesh:

Year:  2012        PMID: 22531225     DOI: 10.1088/0967-3334/33/5/831

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  7 in total

1.  Methods for specific electrode resistance measurement during transcranial direct current stimulation.

Authors:  Niranjan Khadka; Asif Rahman; Chris Sarantos; Dennis Q Truong; Marom Bikson
Journal:  Brain Stimul       Date:  2014-10-17       Impact factor: 8.955

2.  Freezing resistance evaluation of rose stems during frost dehardening using electrical impedance tomography.

Authors:  Juan Zhou; Ruijuan Gong; Ji Qian; Yang Liu; Gang Zhang
Journal:  BMC Plant Biol       Date:  2021-04-26       Impact factor: 4.215

Review 3.  Robust imaging using electrical impedance tomography: review of current tools.

Authors:  Benoit Brazey; Yassine Haddab; Nabil Zemiti
Journal:  Proc Math Phys Eng Sci       Date:  2022-02-02       Impact factor: 2.704

4.  Electrical impedance spectroscopy as electrical biopsy for monitoring radiation sequelae of intestine in rats.

Authors:  Pei-Ju Chao; Eng-Yen Huang; Kuo-Sheng Cheng; Yu-Jie Huang
Journal:  Biomed Res Int       Date:  2013-09-04       Impact factor: 3.411

5.  Electrical impedance imaging system using FPGAs for flexibility and interoperability.

Authors:  Harsh Sohal; Hun Wi; Alistair Lee McEwan; Eung Je Woo; Tong In Oh
Journal:  Biomed Eng Online       Date:  2014-08-30       Impact factor: 2.819

6.  Horses Auto-Recruit Their Lungs by Inspiratory Breath Holding Following Recovery from General Anaesthesia.

Authors:  Martina Mosing; Andreas D Waldmann; Paul MacFarlane; Samuel Iff; Ulrike Auer; Stephan H Bohm; Regula Bettschart-Wolfensberger; David Bardell
Journal:  PLoS One       Date:  2016-06-22       Impact factor: 3.240

7.  System Description and First Application of an FPGA-Based Simultaneous Multi-Frequency Electrical Impedance Tomography.

Authors:  Susana Aguiar Santos; Anne Robens; Anna Boehm; Steffen Leonhardt; Daniel Teichmann
Journal:  Sensors (Basel)       Date:  2016-07-25       Impact factor: 3.576

  7 in total