Literature DB >> 22531059

Comparison of frequency difference reconstruction algorithms for the detection of acute stroke using EIT in a realistic head-shaped tank.

B Packham1, H Koo, A Romsauerova, S Ahn, A McEwan, S C Jun, D S Holder.   

Abstract

Imaging of acute stroke might be possible using multi-frequency electrical impedance tomography (MFEIT) but requires absolute or frequency difference imaging. Simple linear frequency difference reconstruction has been shown to be ineffective in imaging with a frequency-dependant background conductivity; this has been overcome with a weighted frequency difference approach with correction for the background but this has only been validated for a cylindrical and hemispherical tank. The feasibility of MFEIT for imaging of acute stroke in a realistic head geometry was examined by imaging a potato perturbation against a saline background and a carrot-saline frequency-dependant background conductivity, in a head-shaped tank with the UCLH Mk2.5 MFEIT system. Reconstruction was performed with time difference (TD), frequency difference (FD), FD adjacent (FDA), weighted FD (WFD) and weighted FDA (WFDA) linear algorithms. The perturbation in reconstructed images corresponded to the true position to <9.5% of image diameter with an image SNR of >5.4 for all algorithms in saline but only for TD, WFDA and WFD in the carrot-saline background. No reliable imaging was possible with FD and FDA. This indicates that the WFD approach is also effective for a realistic head geometry and supports its use for human imaging in the future.

Entities:  

Mesh:

Year:  2012        PMID: 22531059     DOI: 10.1088/0967-3334/33/5/767

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  9 in total

1.  Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model.

Authors:  Theodore S Bronk; Alicia C Everitt; Ethan K Murphy; Ryan J Halter
Journal:  IEEE Trans Biomed Eng       Date:  2022-04-21       Impact factor: 4.756

2.  Simultaneous Imaging of Bio- and Non-Conductive Targets by Combining Frequency and Time Difference Imaging Methods in Electrical Impedance Tomography.

Authors:  Xue Bai; Dun Liu; Jinzhao Wei; Xu Bai; Shijie Sun; Wenbin Tian
Journal:  Biosensors (Basel)       Date:  2021-05-31

3.  Ex-Vivo Characterization of Bioimpedance Spectroscopy of Normal, Ischemic and Hemorrhagic Rabbit Brain Tissue at Frequencies from 10 Hz to 1 MHz.

Authors:  Lin Yang; Ge Zhang; Jiali Song; Meng Dai; Canhua Xu; Xiuzhen Dong; Feng Fu
Journal:  Sensors (Basel)       Date:  2016-11-18       Impact factor: 3.576

4.  The Frequency Spectral Properties of Electrode-Skin Contact Impedance on Human Head and Its Frequency-Dependent Effects on Frequency-Difference EIT in Stroke Detection from 10Hz to 1MHz.

Authors:  Lin Yang; Meng Dai; Canhua Xu; Ge Zhang; Weichen Li; Feng Fu; Xuetao Shi; Xiuzhen Dong
Journal:  PLoS One       Date:  2017-01-20       Impact factor: 3.240

5.  In Vivo Bioimpedance Spectroscopy Characterization of Healthy, Hemorrhagic and Ischemic Rabbit Brain within 10 Hz-1 MHz.

Authors:  Lin Yang; Wenbo Liu; Rongqing Chen; Ge Zhang; Weichen Li; Feng Fu; Xiuzhen Dong
Journal:  Sensors (Basel)       Date:  2017-04-07       Impact factor: 3.576

6.  A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System.

Authors:  James Avery; Thomas Dowrick; Mayo Faulkner; Nir Goren; David Holder
Journal:  Sensors (Basel)       Date:  2017-01-31       Impact factor: 3.576

7.  Improved Sensing Pulses for Increased Human Head Depth Measurement Sensitivity With Electrical Impedance Spectroscopy.

Authors:  Giorgio Bonmassar; Michael H Lev
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-10       Impact factor: 4.538

8.  Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

Authors:  Jieshi Ma; Canhua Xu; Meng Dai; Fusheng You; Xuetao Shi; Xiuzhen Dong; Feng Fu
Journal:  ScientificWorldJournal       Date:  2014-05-29

Review 9.  A Review on Electrical Impedance Tomography Spectroscopy.

Authors:  Juliana Padilha Leitzke; Hubert Zangl
Journal:  Sensors (Basel)       Date:  2020-09-10       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.