Literature DB >> 22526680

Concentration-dependent cytotoxicity of copper ions on mouse fibroblasts in vitro: effects of copper ion release from TCu380A vs TCu220C intra-uterine devices.

Bianmei Cao1, Yudong Zheng, Tingfei Xi, Chuanchuan Zhang, Wenhui Song, Krishna Burugapalli, Huai Yang, Yanxuan Ma.   

Abstract

Sustained release of copper (Cu) ions from Cu-containing intrauterine devices (CuIUD) is quite efficient for contraception. However, the tissue surrounding the CuIUD is exposed to toxic Cu ion levels. The objective for this study was to quantify the concentration dependent cytotoxic effects of Cu ions and correlate the toxicity due to Cu ion burst release for two popular T-shaped IUDs - TCu380A and TCu220C on L929 mouse fibroblasts. Fibroblasts were cultured in 98 well tissue culture plates and 3-(4,5-dimethylthiazol- 2-yl)-2,5-diphehyltetrazolium bromide (MTT) assay was used to determine their viability and proliferation as a function of time. For cell seeding numbers ranging from 10,000 to 100,000, a maximum culture time of 48 h was identified for fibroblasts without significant reduction in cell proliferation due to contact inhibition. Thus, for Cu cytotoxicity assays, a cell seeding density of 50,000 and a maximum culture time of 48 h in 96 well plates were used. 24 h after cell seeding, culture media were replaced with Cu ion containing media solutions of different concentrations, including 24 and 72 h extracts from TCuIUDs and incubated for a further 24 h. Cell viability decreased with increasing Cu ion concentration, with 30 % and 100 % reduction for 40 μg/ml and 100 μg/ml respectively at 24 h. The cytotoxic effects were further evaluated using light microscopy, apoptosis and cell cycle analysis assays. Fibroblasts became rounded and eventually detached from TCP surface due to Cu ion toxicity. A linear increase in apoptotic cell population with increasing Cu ion concentration was observed in the tested range of 0 to 50 μg/ml. Cell cycle analysis indicated the arrest of cell division for the tested 25 to 50 μg/ml Cu ion treatments. Among the TCuIUDs, TCu220C having 265 mm(2) Cu surface area released 9.08 ± 0.16 and 26.02 ± 0.25 μg/ml, while TCu380A having 400 mm(2) released 96.7 ± 0.11 and 159.3 ± 0.15 μg/ml respectively following 24 and 72 h extractions. The effects of TCuIUD extracts on viability, morphology, apoptosis and cell cycle assay on L929 mouse fibroblasts cells, were appropriate for their respective Cu ion concentrations. Thus, a concentration of about 46 μg/ml (~29 μM) was identified as the LD50 dose for L929 mouse fibroblasts when exposed for 24 h based on our MTT cell viability assay. The burst release of lethal concentration of Cu ions from TCu380A, especially at the implant site, is a cause of concern, and it is advisable to use TCuIUD designs that release Cu ions within cytotoxic limits yet therapeutic, similar to TCu220C.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22526680     DOI: 10.1007/s10544-012-9651-x

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  13 in total

1.  Biocorrosion properties of antibacterial Ti-10Cu sintered alloy in several simulated biological solutions.

Authors:  Cong Liu; Erlin Zhang
Journal:  J Mater Sci Mater Med       Date:  2015-03-04       Impact factor: 3.896

2.  High copper concentrations produce genotoxicity and cytotoxicity in bovine cumulus cells.

Authors:  Juan Mateo Anchordoquy; Juan Patricio Anchordoquy; Noelia Nikoloff; Ana M Pascua; Cecilia C Furnus
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-11       Impact factor: 4.223

3.  Bioinspired ultra-low fouling coatings on medical devices to prevent device-associated infections and thrombosis.

Authors:  Ekrem Ozkan; Arnab Mondal; Megan Douglass; Sean P Hopkins; Mark Garren; Ryan Devine; Rashmi Pandey; James Manuel; Priyadarshini Singha; James Warnock; Hitesh Handa
Journal:  J Colloid Interface Sci       Date:  2021-10-05       Impact factor: 8.128

4.  Feasibility study on Ti-15Mo-7Cu with low elastic modulus and high antibacterial property.

Authors:  Shenshen Cui; Anqi Shi; Yanchun Xie; Hailong Yu; Yongcun Wei; Lei Yang; Gaowu Qin; Erlin Zhang
Journal:  Biometals       Date:  2022-08-22       Impact factor: 3.378

5.  In vitro study on an antibacterial Ti-5Cu alloy for medical application.

Authors:  Zheng Ma; Mei Li; Rui Liu; Ling Ren; Yu Zhang; Haobo Pan; Ying Zhao; Ke Yang
Journal:  J Mater Sci Mater Med       Date:  2016-03-14       Impact factor: 3.896

Review 6.  Covalent labeling of nucleic acids.

Authors:  Nils Klöcker; Florian P Weissenboeck; Andrea Rentmeister
Journal:  Chem Soc Rev       Date:  2020-10-21       Impact factor: 54.564

7.  Hydrogen Peroxide Generation of Copper/Ascorbate Formulations on Cotton: Effect on Antibacterial and Fibroblast Activity for Wound Healing Application.

Authors:  J Vincent Edwards; Nicolette T Prevost; Michael Santiago; Terri von Hoven; Brian D Condon; Huzaifah Qureshi; Dorne R Yager
Journal:  Molecules       Date:  2018-09-19       Impact factor: 4.411

Review 8.  Toxicity of Ag, CuO and ZnO nanoparticles to selected environmentally relevant test organisms and mammalian cells in vitro: a critical review.

Authors:  Olesja Bondarenko; Katre Juganson; Angela Ivask; Kaja Kasemets; Monika Mortimer; Anne Kahru
Journal:  Arch Toxicol       Date:  2013-06-01       Impact factor: 5.153

9.  Use of graphene as protection film in biological environments.

Authors:  Weixia Zhang; Sudarat Lee; Kelly L McNear; Ting Fung Chung; Seunghyun Lee; Kyunghoon Lee; Scott A Crist; Timothy L Ratliff; Zhaohui Zhong; Yong P Chen; Chen Yang
Journal:  Sci Rep       Date:  2014-02-14       Impact factor: 4.379

10.  Antibacterial effect of copper-bearing titanium alloy (Ti-Cu) against Streptococcus mutans and Porphyromonas gingivalis.

Authors:  Rui Liu; Kaveh Memarzadeh; Bei Chang; Yumei Zhang; Zheng Ma; Robert P Allaker; Ling Ren; Ke Yang
Journal:  Sci Rep       Date:  2016-07-26       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.