Literature DB >> 22526193

A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up.

Akram Jawed1, Vijay Kumar, R Malhotra, C S Yadav, S Bhan.   

Abstract

BACKGROUND: Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study.
METHODS: A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared.
RESULTS: At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up.
CONCLUSIONS: Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.

Entities:  

Mesh:

Year:  2012        PMID: 22526193     DOI: 10.1007/s00402-012-1482-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  3 in total

Review 1.  Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis.

Authors:  Joseph T Moskal; Susan G Capps
Journal:  Clin Orthop Relat Res       Date:  2014-03-04       Impact factor: 4.176

Review 2.  No differences between fixed- and mobile-bearing total knee arthroplasty.

Authors:  B L Fransen; D C van Duijvenbode; M J M Hoozemans; B J Burger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-06-20       Impact factor: 4.342

Review 3.  No difference in clinical outcome between fixed- and mobile-bearing TKA: a meta-analysis.

Authors:  Yu-Lin Li; Qiang Wu; Guang-Zhi Ning; Shi-Qing Feng; Qiu-Li Wu; Yan Li; Yan Hao
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-02       Impact factor: 4.342

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.