Continuous arterial positron monitor for quantitation in PET imaging.

A D Nelson1, R F Muzic, F Miraldi, G J Muswick, G P Leisure, W Voelker.   

Abstract

Quantitative measures of physiologic function with PET require continuous monitoring of arterial positron isotope concentration. A device has been developed that automates this process. This device has advantages over manual sampling techniques with syringes since fewer personnel are required, measurements are less error prone, and more continuous measures of arterial positron concentration are available. A constant flow infusion/withdrawal pump withdraws blood from the radial artery through a catheter connected to 0.5 mm inner diameter teflon tubing. This tubing is wrapped around a 50 mm thick by 50 mm diameter NaI(T1) crystal that is interfaced to a photomultiplier tube (PMT) and encased in a cylindrical lead shield. This crystal detects 511 Kev photons that result from positron annihilation. The device sensitivity is greater than 240 (cts/sec)/(microCi/ml) corresponding to a peak activity of approximately 10,000 cts/sec for a 50 mCi bolus injection in an adult. The system dynamic response has been measured and the true arterial input function is recovered by deconvolution. The system has been used clinically for more than 400 human PET studies and has been a reliable continuous monitor of arterial positron concentration.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2252609

Source DB:  PubMed          Journal:  Am J Physiol Imaging        ISSN: 0885-8276


  6 in total

1.  Iterative optimal design of PET experiments for estimating beta-adrenergic receptor concentration.

Authors:  R F Muzic; G M Saidel; N Zhu; A D Nelson; L Zheng; M S Berridge
Journal:  Med Biol Eng Comput       Date:  2000-11       Impact factor: 2.602

2.  Smoking produces rapid rise of [11C]nicotine in human brain.

Authors:  Marc S Berridge; Scott M Apana; Kenichi K Nagano; Catherine E Berridge; Gregory P Leisure; Mark V Boswell
Journal:  Psychopharmacology (Berl)       Date:  2010-03-16       Impact factor: 4.530

3.  Dexamethasone-induced insulin resistance: kinetic modeling using novel PET radiopharmaceutical 6-deoxy-6-[(18)F]fluoro-D-glucose.

Authors:  Kuan-Hao Su; Visvanathan Chandramouli; Faramarz Ismail-Beigi; Raymond F Muzic
Journal:  Mol Imaging Biol       Date:  2014-10       Impact factor: 3.488

4.  Hyperglycemia-induced stimulation of glucose transport in skeletal muscle measured by PET-[18F]6FDG and [18F]2FDG.

Authors:  Hsuan-Ming Huang; Visvanathan Chandramouli; Faramarz Ismail-Beigi; Raymond F Muzic
Journal:  Physiol Meas       Date:  2012-09-18       Impact factor: 2.833

5.  Development of a blood sample detector for multi-tracer positron emission tomography using gamma spectroscopy.

Authors:  Carlos Velasco; Adriana Mota-Cobián; Jesús Mateo; Samuel España
Journal:  EJNMMI Phys       Date:  2019-12-16

6.  Development and performance test of an online blood sampling system for determination of the arterial input function in rats.

Authors:  Friedrich Roehrbacher; Jens P Bankstahl; Marion Bankstahl; Thomas Wanek; Johann Stanek; Michael Sauberer; Julia Muellauer; Thales Schroettner; Oliver Langer; Claudia Kuntner
Journal:  EJNMMI Phys       Date:  2015-01-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.