Literature DB >> 22524487

Intubation of the morbidly obese patient: GlideScope(®) vs. Fastrach™.

M Ydemann1, L Rovsing, A L Lindekaer, K S Olsen.   

Abstract

BACKGROUND: Several potential problems can arise from airway management in morbidly obese patients, including difficult mask ventilation and difficult intubation. We hypothesised that endotracheal intubation of morbidly obese patients would be more rapid using the GlideScope(®) (GS) (Verathon Inc Corporate Headquarters, Bothell, WA, USA) than with the Fastrach™ (FT) (The Laryngeal Mask Company Ltd, Le Rocher, Victoria, Mahe, Seychelles).
METHODS: One hundred patients who were scheduled for bariatric surgery were randomised to tracheal intubation using either a GS or an FT. The inclusion criteria were age 18-60 years and a body mass index of ≥ 35 kg/m(2) . The primary end point was intubation time, and if intubation was not achieved after two attempts, the other method was used for the third attempt.
RESULTS: The mean intubation time was 49 s using the GS and 61 s using the FT (P = 0.86). A total of 92% and 84% of the patients were intubated on the first attempt using the GS and the FT, respectively. One tracheal intubation failed on the second attempt when the GS was used, and five failed on the second attempt when the FT was used. There were no incidents of desaturation and no differences between the groups in terms of mucosal damage or intubation difficulty. We experienced one oesophageal intubation using GS and six oesophageal intubations in five patients using FT. There was no difference between the pain scores or incidence of post-operative hoarseness associated with the two intubation techniques.
CONCLUSION: No significant difference between the two methods was found. The GS and the FT may therefore be considered to be equally good when intubating morbidly obese patients.
© 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2012        PMID: 22524487     DOI: 10.1111/j.1399-6576.2012.02693.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  5 in total

1.  The optimum sevoflurane concentration for supraglottic airway device Blockbuster™ insertion with spontaneous breathing in obese patients: a prospective observational study.

Authors:  Haixia Wang; Xue Gao; Wei Wei; Huihui Miao; Hua Meng; Ming Tian
Journal:  BMC Anesthesiol       Date:  2017-11-28       Impact factor: 2.217

Review 2.  Airway management in patients suffering from morbid obesity.

Authors:  Wan Jane Liew; Asadi Negar; Prit Anand Singh
Journal:  Saudi J Anaesth       Date:  2022-06-20

3.  The difficult airway with recommendations for management--part 1--difficult tracheal intubation encountered in an unconscious/induced patient.

Authors:  J Adam Law; Natasha Broemling; Richard M Cooper; Pierre Drolet; Laura V Duggan; Donald E Griesdale; Orlando R Hung; Philip M Jones; George Kovacs; Simon Massey; Ian R Morris; Timothy Mullen; Michael F Murphy; Roanne Preston; Viren N Naik; Jeanette Scott; Shean Stacey; Timothy P Turkstra; David T Wong
Journal:  Can J Anaesth       Date:  2013-10-17       Impact factor: 5.063

4.  Does the revised intubating laryngeal tube (ILTS-D2) perform better than the intubating laryngeal mask (Fastrach)? - a randomised simulation research study.

Authors:  Thomas Ott; Katharina Tschöpe; Gerrit Toenges; Holger Buggenhagen; Kristin Engelhard; Marc Kriege
Journal:  BMC Anesthesiol       Date:  2020-05-11       Impact factor: 2.217

5.  Comparison of Videolaryngoscope and Intubating Laryngeal Mask Airway for Tracheal Intubation with Manual-in-line Stabilization in Patients Undergoing Cervical Spine Surgery.

Authors:  Reena Jakhar; Deepti Saigal; Suniti Kale; Shipra Aggarwal
Journal:  Anesth Essays Res       Date:  2020-11-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.