Literature DB >> 22522982

Worldwide experience with the 29-mm Edwards SAPIEN XT™ transcatheter heart valve in patients with large aortic annulus.

Olaf Wendler1, Matthias Thielmann, Holger Schroefel, Ardawan Rastan, Hendrik Treede, Thorsten Wahlers, Walther Eichinger, Thomas Walther.   

Abstract

OBJECTIVES: The feasibility of transcatheter aortic valve implantation is limited by the diameter of the aortic annulus. Patients with an annulus of >25 mm were previously unsuitable for transcatheter valve implantation using the Edwards SAPIEN™ bioprosthesis. The 29-mm Edwards SAPIEN XT™ bioprosthesis is a new device suitable for transapical aortic valve implantation in patients with a large aortic annulus. We report the worldwide experience in using this device.
METHODS: A total of 120 patients (age 80.3 ± 5.7 years, 2.5% female) underwent transapical aortic valve implantation using a 29-mm Edwards SAPIEN XT™ bioprosthesis between the period of December 2009 and February 2011. The mean values of the logistic EuroSCORE and the STS score were 23.4 ± 7.7 and 6.8 ± 4.0, respectively. A total of 20 centres participated in this study and all patients gave written informed consent.
RESULTS: There were two conversions to open heart surgery (1.7%) and four patients (3.3%) required a temporary cardiopulmonary bypass support. A mean of 131 ± 68.0-ml contrast dye was used. The procedural success, defined as one valve implanted, no aortic regurgitation (AR) >2+ and a transcatheter valve in the appropriate position, was achieved in 95.8% of patients. Early postoperative complications at ≤ 30 days included renal failure requiring temporary dialysis (n = 7, 5.8%), reopening for bleeding (n = 5, 4.2%), stroke (n = 2, 1.7%), respiratory complications requiring prolonged mechanical ventilation (n = 11, 9.2%) and postoperative pacemaker implantation (n = 15/12.5%). The Kaplan-Meier survival estimates were 95.8% at 30-day, 88.9% at 6-month and 79.8% at the 1-year follow-up. The controlled echocardiography data at 30 days (n = 95) revealed no/trivial AR in 79 (84.1%), mild AR in 12 (12.8%) and moderate in two (2.2%) patients. The univariable analysis of baseline characteristics revealed no predictor for 30-day mortality.
CONCLUSIONS: The 29-mm Edwards SAPIEN XT™ bioprosthesis provides an excellent outcome in patients with a large aortic annulus undergoing transapical aortic valve implantation. Using this larger transcatheter heart valve, a broader population of high-risk elderly patients with aortic stenosis can be treated by minimally invasive transapical implantation techniques.

Entities:  

Mesh:

Year:  2012        PMID: 22522982     DOI: 10.1093/ejcts/ezs203

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  3 in total

Review 1.  Causes of Death Following Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Tian-Yuan Xiong; Yan-Biao Liao; Zhen-Gang Zhao; Yuan-Ning Xu; Xin Wei; Zhi-Liang Zuo; Yi-Jian Li; Jia-Yu Cao; Hong Tang; Hasan Jilaihawi; Yuan Feng; Mao Chen
Journal:  J Am Heart Assoc       Date:  2015-09-21       Impact factor: 5.501

2.  Challenges in cardiac device innovation: is neuroimaging an appropriate endpoint? Consensus from the 2013 Yale-UCL Cardiac Device Innovation Summit.

Authors:  Stephanie M Meller; Andreas Baumbach; Szilard Voros; Michael Mullen; Alexandra J Lansky
Journal:  BMC Med       Date:  2013-12-11       Impact factor: 8.775

3.  A review of most relevant complications of transcatheter aortic valve implantation.

Authors:  Siyamek Neragi-Miandoab; Robert E Michler
Journal:  ISRN Cardiol       Date:  2013-05-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.