Modelling city-scale facade leaching of biocide by rainfall.

Sylvain Coutu1, Chiara Rota, Luca Rossi, D A Barry.   

Abstract

A methodology is presented for estimating, at the city scale, the amount of biocide released from facades during rain events. The methodology consists of two elements. First, leaching of a single facade is simulated using a two-region model, one region for the biocide in the facade and the other for that in the flow over the facade surface. In the latter region, water advection moves the biocide to the base of the facade, and so into the environment. Rates of detachment and deposition define the exchange process between the two regions. The two-region model was calibrated on laboratory data, and afterward applied at city scale to Lausanne, Switzerland (200,000 inhabitants). The city-scale application uses the second element of the methodology, which consists of an estimate of the exposure of the city's facades to rainfall, and relating that rainfall to the over-facade flow in the calibrated single-facade model. This results in a straightforward translation of over-facade flow volume to facade paint age, a necessary connection since facade leaching is dependent on paint age. For Lausanne, it was estimated that approximately 30% of the mass of biocides applied annually is released into the environment.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22521950     DOI: 10.1016/j.watres.2012.03.064

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  1 in total

1.  Antifungal efficiency assessment of the TiO2 coating on façade paints.

Authors:  Snežana B Vučetić; Ognjen Lj Rudić; Siniša L Markov; Oskar J Bera; Ana M Vidaković; Andrijana S Sever Skapin; Jonjaua G Ranogajec
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-31       Impact factor: 4.223