BACKGROUND: A new generation of balloon-expandable valves (e.g. Edwards SAPIEN XT) enables the use of a decreased sheath size using the NovaFlex™ delivery system for transfemoral transcatheter aortic valve implantation (TAVI). However, there are few data analysing the efficacy and safety of this new prosthesis. AIMS: To evaluate periprocedural and 30-day clinical outcomes using the Edwards SAPIEN XT compared with the first-generation Edwards SAPIEN prosthesis. METHODS: Between May 2006 and October 2011, consecutive high-risk or non-operable patients with severe aortic stenosis had TAVI using an Edwards SAPIEN or SAPIEN XT prosthesis. Valve Academic Research Consortium endpoints were used. RESULTS: Of 250 patients who underwent TAVI, 190 were performed transfemorally (78 SAPIEN and 112 SAPIEN XT). Transfemoral access was possible more often using SAPIEN XT (112/123 [91.1%] vs 78/127 [61.4%]; P<0.001). Mean logistic EuroSCORE was significantly lower in the SAPIEN XT group (18.1±11.0% vs 27.3±11.1%; P<0.0001), and the iliofemoral artery minimal lumen diameter was smaller (6.7±1.2 vs 8.5±1.3mm; P<0.0001). Device success was similar in both groups (95.5% for SAPIEN XT and 93.6% for SAPIEN), as was the 30-day combined safety endpoint (15.2% and 17.9%, respectively). At 30days, prosthesis performance was similar in both groups. CONCLUSIONS: Short-term safety and performance analysis of the latest generation of balloon-expandable valve, the SAPIEN XT, seem similar to the previous generation. However, transfemoral implantation is more often possible, related to sheath size reduction.
BACKGROUND: A new generation of balloon-expandable valves (e.g. Edwards SAPIEN XT) enables the use of a decreased sheath size using the NovaFlex™ delivery system for transfemoral transcatheter aortic valve implantation (TAVI). However, there are few data analysing the efficacy and safety of this new prosthesis. AIMS: To evaluate periprocedural and 30-day clinical outcomes using the Edwards SAPIEN XT compared with the first-generation Edwards SAPIEN prosthesis. METHODS: Between May 2006 and October 2011, consecutive high-risk or non-operable patients with severe aortic stenosis had TAVI using an Edwards SAPIEN or SAPIEN XT prosthesis. Valve Academic Research Consortium endpoints were used. RESULTS: Of 250 patients who underwent TAVI, 190 were performed transfemorally (78 SAPIEN and 112 SAPIEN XT). Transfemoral access was possible more often using SAPIEN XT (112/123 [91.1%] vs 78/127 [61.4%]; P<0.001). Mean logistic EuroSCORE was significantly lower in the SAPIEN XT group (18.1±11.0% vs 27.3±11.1%; P<0.0001), and the iliofemoral artery minimal lumen diameter was smaller (6.7±1.2 vs 8.5±1.3mm; P<0.0001). Device success was similar in both groups (95.5% for SAPIEN XT and 93.6% for SAPIEN), as was the 30-day combined safety endpoint (15.2% and 17.9%, respectively). At 30days, prosthesis performance was similar in both groups. CONCLUSIONS: Short-term safety and performance analysis of the latest generation of balloon-expandable valve, the SAPIEN XT, seem similar to the previous generation. However, transfemoral implantation is more often possible, related to sheath size reduction.
Authors: Albert Markus Kasel; Salvatore Cassese; Thomas Ischinger; Alexander Leber; Diethmar Antoni; Gotthard Riess; Jayshree Vogel; Adnan Kastrati; Walter Eichinger; Ellen Hoffmann Journal: Am J Cardiovasc Dis Date: 2014-06-28
Authors: Zisis Dimitriadis; Werner Scholtz; Stephan M Ensminger; Cornelia Piper; Thomas Bitter; Marcus Wiemer; Marios Vlachojannis; Jochen Börgermann; Lothar Faber; Dieter Horstkotte; Jan Gummert; Smita Scholtz Journal: PLoS One Date: 2017-08-24 Impact factor: 3.240
Authors: Katarzyna Czerwińska-Jelonkiewicz; Ilona Michałowska; Adam Witkowski; Maciej Dąbrowski; Ewa Księżycka-Majczyńska; Zbigniew Chmielak; Krzysztof Kuśmierski; Tomasz Hryniewiecki; Marcin Demkow; Janina Stępińska Journal: J Thromb Thrombolysis Date: 2014-05 Impact factor: 2.300
Authors: Gerhard Schymik; Valentin Herzberger; Jens Bergmann; Peter Bramlage; Lars O Conzelmann; Alexander Würth; Armin Luik; Holger Schröfel; Panagiotis Tzamalis Journal: BMJ Open Date: 2018-10-25 Impact factor: 2.692