Literature DB >> 22519179

[Colorimetric detection of norovirus genotype GII by reverse transcription loop-mediated isothermal amplification].

Jian-Ming Luo1, Xi-Yang Wu, Zi-Qian Xu, Le Luo, Kai Nie, Meng-Jie Yang, Ya-Lan Zeng, Zhao-Jun Duan, Xue-Jun Ma.   

Abstract

A simple, rapid and sensitive colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP) method was established to detect norovirus genotype GII. The method employed a set of six specially designed primers that recognized eight distinct sequences of RNA-dependant RNA polymerase and capsid protein gene for amplification of nucleic acid under isothermal conditions at 65 degrees C for 60 minutes. The amplification process of RT-LAMP was monitored by the addition of HNB (Hydroxy naphthol blue) dye prior to amplification. A positive reaction was indicated by a color change from violet to sky blue and confirmed by agarose electrophoresis. The specificity of the RT-LAMP was validated by detecting several different diarrhea viruses including norovirus genotype GII. The sensitivity was determined by serial dilutions of RNA molecules from in vitro transcription of norovirus genotype GII in parallel with conventional RT-PCR detection. The assay was further evaluated with 93 clinical specimens of diarrhea patients. The results showed that the sensitivity of RT-LAMP was 1 000 copies/microL with a high specificity and the relative sensitivity was at the same level as that of conventional RT-PCR. Positive rate of RT-LAMP in analysis of clinical specimens was approximately the same as that of conventional RT-PCR as well. This colorimetric RT-LAMP assay was potential for rapid detection of norovirus genotype GII on spot due to the observation of visual result with high specificity and sensitivity, time-saving and cost benefit.

Entities:  

Mesh:

Year:  2012        PMID: 22519179

Source DB:  PubMed          Journal:  Bing Du Xue Bao        ISSN: 1000-8721


  3 in total

1.  Visual detection of norovirus genogroup II by reverse transcription loop-mediated isothermal amplification with hydroxynaphthol blue dye.

Authors:  Jianming Luo; Ziqian Xu; Kai Nie; Xiong Ding; Li Guan; Ji Wang; Yuying Xian; Xiyang Wu; Xuejun Ma
Journal:  Food Environ Virol       Date:  2014-04-22       Impact factor: 2.778

2.  Development of a recombinase-aided amplification assay for rapid detection of human norovirus GII.4.

Authors:  Zhiwei Qin; Liang Xue; Weicheng Cai; Junshan Gao; Yueting Jiang; Jiale Yang; Yanhui Liang; Linping Wang; Jumei Zhang; Yongdan Hu; Qingping Wu
Journal:  BMC Infect Dis       Date:  2021-03-09       Impact factor: 3.090

3.  Pooled analysis of LAMP assay for the diagnosis of norovirus infection.

Authors:  Xi-Feng Qian; Ai-Ling Duan; Rong-Xian Huang; Nan-Xi Li; Ya-Ping Li; Xu-Guang Guo
Journal:  J Clin Lab Anal       Date:  2021-07-31       Impact factor: 2.352

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.