Literature DB >> 22516142

Implantable enzyme amperometric biosensors.

Christian N Kotanen1, Francis Gabriel Moussy2, Sandro Carrara3, Anthony Guiseppi-Elie4.   

Abstract

The implantable enzyme amperometric biosensor continues as the dominant in vivo format for the detection, monitoring and reporting of biochemical analytes related to a wide range of pathologies. Widely used in animal studies, there is increasing emphasis on their use in diabetes care and management, the management of trauma-associated hemorrhage and in critical care monitoring by intensivists in the ICU. These frontier opportunities demand continuous indwelling performance for up to several years, well in excess of the currently approved seven days. This review outlines the many challenges to successful deployment of chronically implantable amperometric enzyme biosensors and emphasizes the emerging technological approaches in their continued development. The foreign body response plays a prominent role in implantable biotransducer failure. Topics considering the approaches to mitigate the inflammatory response, use of biomimetic chemistries, nanostructured topographies, drug eluting constructs, and tissue-to-device interface modulus matching are reviewed. Similarly, factors that influence biotransducer performance such as enzyme stability, substrate interference, mediator selection and calibration are reviewed. For the biosensor system, the opportunities and challenges of integration, guided by footprint requirements, the limitations of mixed signal electronics, and power requirements, has produced three systems approaches. The potential is great. However, integration along the multiple length scales needed to address fundamental issues and integration across the diverse disciplines needed to achieve success of these highly integrated systems, continues to be a challenge in the development and deployment of implantable amperometric enzyme biosensor systems.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22516142     DOI: 10.1016/j.bios.2012.03.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  19 in total

1.  Facile fabrication of flexible glutamate biosensor using direct writing of platinum nanoparticle-based nanocomposite ink.

Authors:  Tran N H Nguyen; James K Nolan; Hyunsu Park; Stephanie Lam; Mara Fattah; Jessica C Page; Hang-Eun Joe; Martin B G Jun; Hyungwoo Lee; Sang Joon Kim; Riyi Shi; Hyowon Lee
Journal:  Biosens Bioelectron       Date:  2019-01-31       Impact factor: 10.618

2.  Macro-/meso-porous NiCo2O4 synthesized by template-free solution combustion to enhance the performance of a nonenzymatic amperometric glucose sensor.

Authors:  Xuechun Xiao; Xuanming Zhang; Zhanyu Zhang; Junda You; Sirui Liu; Yude Wang
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

Review 3.  Semi-Implantable Bioelectronics.

Authors:  Jiaru Fang; Shuang Huang; Fanmao Liu; Gen He; Xiangling Li; Xinshuo Huang; Hui-Jiuan Chen; Xi Xie
Journal:  Nanomicro Lett       Date:  2022-05-28

Review 4.  Current Approaches to Monitor Macromolecules Directly from the Cerebral Interstitial Fluid.

Authors:  Marie-Laure Custers; Liam Nestor; Dimitri De Bundel; Ann Van Eeckhaut; Ilse Smolders
Journal:  Pharmaceutics       Date:  2022-05-13       Impact factor: 6.525

Review 5.  Implantable nanosensors: toward continuous physiologic monitoring.

Authors:  Timothy T Ruckh; Heather A Clark
Journal:  Anal Chem       Date:  2013-12-10       Impact factor: 6.986

6.  Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size.

Authors:  Yan Wang; Santhisagar Vaddiraju; Bing Gu; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

7.  Substrate specificity and interferences of a direct-electron-transfer-based glucose biosensor.

Authors:  Alfons K G Felice; Christoph Sygmund; Wolfgang Harreither; Roman Kittl; Lo Gorton; Roland Ludwig
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

Review 8.  CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review.

Authors:  Haitao Li; Xiaowen Liu; Lin Li; Xiaoyi Mu; Roman Genov; Andrew J Mason
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

9.  Supramolecular glucose oxidase-SWNT conjugates formed by ultrasonication: effect of tube length, functionalization and processing time.

Authors:  Olukayode Karunwi; Anthony Guiseppi-Elie
Journal:  J Nanobiotechnology       Date:  2013-02-20       Impact factor: 10.435

10.  Glucose Sensing Using Capacitive Biosensor Based on Polyvinylidene Fluoride Thin Film.

Authors:  Ambran Hartono; Edi Sanjaya; Ramli Ramli
Journal:  Biosensors (Basel)       Date:  2018-01-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.