Pseudomonas aeruginosa respiratory tract infections associated with contaminated ultrasound gel used for transesophageal echocardiography - Michigan, December 2011-January 2012.

.   

Abstract

In late December 2011, the Department of Epidemiology at Beaumont Health System (BHS) in Royal Oak, Michigan, noted an increase in the number of positive respiratory cultures in one surgical intensive-care unit (ICU), prompting further investigation. The increase in positive cultures was attributed entirely to Pseudomonas aeruginosa. Investigation by BHS staff members found that all of these positive cultures were related to use of ultrasound transmission gel from a single manufacturer during transesophageal echocardiography. Seven patients were infected with P. aeruginosa based on National Healthcare Safety Network (NHSN) criteria, and nine were colonized. Cultures from one open and one unopened bottle of the gel grew P. aeruginosa closely related to the outbreak strain based on molecular typing via repetitive extragenic palindromic polymerase chain reaction (rep-PCR). The Oakland County Health Department, the Michigan Department of Community Health, and the Food and Drug Administration (FDA) were notified of the findings. On January 23, all implicated ultrasound gel in multiuse bottles was removed from BHS facilities and replaced with a single-use, sterile ultrasound gel for all potentially invasive procedures. On April 18, FDA issued a Safety Communication* advising health-care professionals and facilities not to use certain lot numbers of the ultrasound transmission gel and further advising that the only ultrasound gel that is sterile is unopened gel in containers labeled as sterile. To date, no further respiratory cultures have been positive for P. aeruginosa.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22513528

Source DB:  PubMed          Journal:  MMWR Morb Mortal Wkly Rep        ISSN: 0149-2195            Impact factor:   17.586


  5 in total

1.  Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology.

Authors:  Christiane Marita Nyhsen; Hilary Humphreys; Carlos Nicolau; Gerhard Mostbeck; Michel Claudon
Journal:  Insights Imaging       Date:  2016-10-24

2.  Mortality, morbidity, and cardiac surgery in Injection Drug Use (IDU)-associated versus non-IDU infective endocarditis: The need to expand substance use disorder treatment and harm reduction services.

Authors:  Kinna Thakarar; Kristina E Rokas; F L Lucas; Spencer Powers; Elizabeth Andrews; Christina DeMatteo; Deirdre Mooney; Marcella H Sorg; August Valenti; Mylan Cohen
Journal:  PLoS One       Date:  2019-11-26       Impact factor: 3.240

Review 3.  Guideline from the Japanese society of echocardiography: guidance for the management and maintenance of echocardiography equipment: 2022 focused update.

Authors:  Masao Daimon; Hiroyuki Iwano; Tetsuari Onishi; Takahiro Ohara; Hidekazu Tanaka; Yutaka Hirano; Hirotsugu Yamada; Chisato Izumi; Satoshi Nakatani
Journal:  J Echocardiogr       Date:  2022-09-02

4.  Therapeutic Management of Pseudomonas aeruginosa Bloodstream Infection Non-Susceptible to Carbapenems but Susceptible to "Old" Cephalosporins and/or to Penicillins.

Authors:  Ronit Zaidenstein; Asaf Miller; Ruthy Tal-Jasper; Hadas Ofer-Friedman; Menachem Sklarz; David E Katz; Tsillia Lazarovitch; Paul R Lephart; Bethlehem Mengesha; Oran Tzuman; Mor Dadon; Chen Daniel; Jacob Moran-Gilad; Dror Marchaim
Journal:  Microorganisms       Date:  2018-01-16

5.  Outbreak of Acinetobacter baumannii associated with extrinsic contamination of ultrasound gel in a tertiary centre burn unit.

Authors:  Kruti J Yagnik; Gautam Kalyatanda; Anthony P Cannella; Lennox K Archibald
Journal:  Infect Prev Pract       Date:  2019-06-27