Literature DB >> 22513498

Alveolar bone stress around implants with different abutment angulation: an FE-analysis of anterior maxilla.

Roozbeh Sadrimanesh1, Hakimeh Siadat, Pooyan Sadr-Eshkevari, Abbas Monzavi, Peter Maurer, Ashkan Rashad.   

Abstract

OBJECTIVES: To comparatively assess the masticatory stress distribution in bone around implants placed in the anterior maxilla with three different labial inclinations.
MATERIALS AND METHODS: Three-dimensional finite element models were fabricated for three situations in anterior maxilla: (1) a fixture in contact with buccal cortical plate restored by straight abutment, (2) a fixture inclined at 15 degrees, and (3) 20 degrees labially restored with corresponding angled abutment. A palatal bite force of 146 N was applied to a point 3 mm below the incisal edge. Stress distribution around the bone-fixture interface was determined using ANSYS software.
RESULTS: The maximum compressive stress, concentrated in the labial crestal cortical bone, was measured to be 62, 108, and 122 MPa for 0-, 15-, and 20-degree labially inclined fixtures, respectively. The maximum tensile stress, concentrated in the palatal crestal cortical bone, was measured to be 60, 108, and 120 MPa for 0-, 15-, and 20-degree labially inclined fixtures, respectively.
CONCLUSIONS: While all compressive stress values were under the cortical yield strength of 169 MPa, tensile stress values partially surpassed the yield strength (104 MPa) especially when a 20-degree inclination was followed for fixture placement.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22513498     DOI: 10.1097/ID.0b013e31824c302e

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  5 in total

1.  A further finite element stress analysis of angled abutments for an implant placed in the anterior maxilla.

Authors:  Dong Wu; Kebin Tian; Jiang Chen; Hua Jin; Wenxiu Huang; Yuyu Liu
Journal:  Comput Math Methods Med       Date:  2015-02-23       Impact factor: 2.238

Review 2.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

3.  A Comparative Analysis of Implants Presenting Different Diameters: Extra-Narrow, Narrow and Conventional.

Authors:  Henrique Tuzzolo Neto; Alessandra Sayuri Tuzita; Sérgio Alexandre Gehrke; Renata de Vasconcellos Moura; Márcio Zaffalon Casati; Alfredo Mikail Melo Mesquita
Journal:  Materials (Basel)       Date:  2020-04-17       Impact factor: 3.623

4.  Long-Term Fatigue and Its Probability of Failure Applied to Dental Implants.

Authors:  María Prados-Privado; Juan Carlos Prados-Frutos; Sérgio Alexandre Gehrke; Mariano Sánchez Siles; José Luis Calvo Guirado; José Antonio Bea
Journal:  Biomed Res Int       Date:  2016-07-19       Impact factor: 3.411

Review 5.  Additive Manufacturing for Guided Bone Regeneration: A Perspective for Alveolar Ridge Augmentation.

Authors:  Patrick Rider; Željka Perić Kačarević; Said Alkildani; Sujith Retnasingh; Reinhard Schnettler; Mike Barbeck
Journal:  Int J Mol Sci       Date:  2018-10-24       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.