Literature DB >> 22511311

Paclitaxel versus sirolimus eluting stents in diabetic patients: does stent type and/or stent diameter matter?: long-term clinical outcome of 2,429-patient multicenter registry.

Giuseppe Tarantini1, Michela Facchin, Davide Capodanno, Giuseppe Musumeci, Francesco Saia, Alberto Menozzi, Emanuele Meliga, Massimo Mancone, Corrado Lettieri, Corrado Tamburino.   

Abstract

BACKGROUND: Drug-eluting stents (DES) are more effective in reducing restenosis than bare-metal stents. Less certain is the relative performance of the two widely used DES-sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES)-in diabetic patients undergoing percutaneous coronary intervention (PCI).
OBJECTIVES: We studied the long-term effectiveness and safety of SES versus PES in diabetic patients, overall and grouped by the size of the stent placed in the native-stented vessel.
METHODS: Data were obtained from an observational, multicenter registry of 2,429 consecutive patients with DM who underwent PCI between August 2003 and August 2009 with SES (n = 1,370) or PES (n = 1,059). Data were analyzed separately for patients with small stents (<3.0 mm, n = 1,274) vs. only large (≥3.0 mm, n = 1,155).
RESULTS: At Cox-adjusted analysis of the overall cohort, there was no significant difference between SES and PES with regard to death/myocardial infarction (D/MI) (P = 0.6) or target lesion revascularization (TLR) (P = 0.3) either in "small-stent" (D/MI, P = 0.8; TLR, P = 0.2) or "large stent" group (D/MI, P = 0.8; TLR, P = 0.4) throughout 1 to 5-year follow-up. These results were confirmed by sensitivity, propensity-score matched analysis (717 matched pairs) that failed to find differences in the safety and efficacy between SES and PES.
CONCLUSIONS: In this large observational study, PES and SES were equally safe and efficacious in diabetic patients undergoing PCI in clinical practice, regardless of the stent size.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22511311     DOI: 10.1002/ccd.24445

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  The use of the Cre8 Stent in Patients With Diabetes Mellitus.

Authors:  Didier Carrié
Journal:  Interv Cardiol       Date:  2016-05

2.  Mortality and Paclitaxel-Coated Devices: An Individual Patient Data Meta-Analysis.

Authors:  Krishna J Rocha-Singh; Sue Duval; Michael R Jaff; Peter A Schneider; Gary M Ansel; Sean P Lyden; Christopher M Mullin; John P A Ioannidis; Sanjay Misra; Abraham R Tzafriri; Elazer R Edelman; Juan F Granada; Christopher J White; Joshua A Beckman
Journal:  Circulation       Date:  2020-05-06       Impact factor: 29.690

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.