Literature DB >> 22509440

Cases of hemolytic anemia with periprosthetic leaks evaluated by real-time 3-dimensional transesophageal echocardiography.

Eui-Jong Chung1, Tae-Yop Kim, Jong Min Hwang, Sang-Phil Kim, Hyun Suk Yang.   

Abstract

Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.

Entities:  

Keywords:  Hemolytic anemia; Three-dimensional echocardiography

Year:  2012        PMID: 22509440      PMCID: PMC3324729          DOI: 10.4250/jcu.2012.20.1.52

Source DB:  PubMed          Journal:  J Cardiovasc Ultrasound        ISSN: 1975-4612


  10 in total

1.  Practical guide for three-dimensional transthoracic echocardiography using a fully sampled matrix array transducer.

Authors:  Hyun Suk Yang; Ramesh C Bansal; Farouk Mookadam; Bijoy K Khandheria; A Jamil Tajik; Krishnaswamy Chandrasekaran
Journal:  J Am Soc Echocardiogr       Date:  2008-09       Impact factor: 5.251

2.  Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

Authors:  Lissa Sugeng; Stanton K Shernan; Lynn Weinert; Doug Shook; Jai Raman; Valluvan Jeevanandam; Frank DuPont; John Fox; Victor Mor-Avi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2008-10-10       Impact factor: 5.251

3.  Images in cardiovascular medicine. Real-time 3-dimensional transesophageal echocardiography: novel utility in atrial fibrillation ablation with a prosthetic mitral valve.

Authors:  Hyun Suk Yang; Komandoor Srivathsan; Eric Wissner; Krishnaswamy Chandrasekaran
Journal:  Circulation       Date:  2008-04-08       Impact factor: 29.690

4.  Guidelines for reporting morbidity and mortality after cardiac valvular operations. Ad Hoc Liaison Committee for Standardizing Definitions of Prosthetic Heart Valve Morbidity of The American Association for Thoracic Surgery and The Society of Thoracic Surgeons.

Authors:  L H Edmunds; R E Clark; L H Cohn; G L Grunkemeier; D C Miller; R D Weisel
Journal:  J Thorac Cardiovasc Surg       Date:  1996-09       Impact factor: 5.209

5.  Intravascular hemolysis in patients with new-generation prosthetic heart valves: a prospective study.

Authors:  Gianclaudio Mecozzi; Aldo D Milano; Marco De Carlo; Flavia Sorrentino; Stefano Pratali; Carmela Nardi; Uberto Bortolotti
Journal:  J Thorac Cardiovasc Surg       Date:  2002-03       Impact factor: 5.209

6.  Clinical experience of 473 patients with the omnicarbon prosthetic heart valve.

Authors:  Y Iguro; Y Moriyama; A Yamaoka; M Yamashita; S Shimokawa; H Toyohira; A Taira
Journal:  J Heart Valve Dis       Date:  1999-11

7.  Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St. Jude Medical prostheses, and influence of prosthetic type, position, size and number.

Authors:  J Skoularigis; M R Essop; D Skudicky; S J Middlemost; P Sareli
Journal:  Am J Cardiol       Date:  1993-03-01       Impact factor: 2.778

8.  Hemolysis after mitral valve repair: a report of five cases and literature review.

Authors:  E Demirsoy; O Yilmaz; G Sirin; T Baran; S Tekin; D Sener; B Sonmez
Journal:  J Heart Valve Dis       Date:  2008-01

9.  Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation.

Authors:  M J Garcia; P Vandervoort; W J Stewart; B W Lytle; D M Cosgrove; J D Thomas; B P Griffin
Journal:  J Am Coll Cardiol       Date:  1996-02       Impact factor: 24.094

Review 10.  Evaluation of hemolysis in patients with prosthetic heart valves.

Authors:  R Maraj; L E Jacobs; A Ioli; M N Kotler
Journal:  Clin Cardiol       Date:  1998-06       Impact factor: 2.882

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.