Literature DB >> 22505861

Neurophysiological two-channel polysomnographic device in the diagnosis of sleep apnea.

Alex Ferré1, Gabriel Sampol, Maria José Jurado, Roser Cambrodi, Patricia Lloberes, Odile Romero.   

Abstract

STUDY
OBJECTIVE: Our objective was to evaluate a portable device (Somté, Compumedics, Australia), which incorporates 2 neurophysiological channels (electroencephalography and electrooculography) with cardiorespiratory monitoring for the diagnosis of obstructive sleep apnea (OSA).
METHOD: Full polysomnography (PSG) and Somté recordings were simultaneously performed in 68 patients with suspected OSA. Data were analyzed blindly by 2 scorers.
RESULTS: A good agreement between methods in sleep efficiency was observed (68.8% [18.4] with PSG vs 68% [19.1] with Somté [p: n.s.] for scorer 1, and 67.5% [19.1] vs 68.4% [18.5; p: n.s.] for scorer 2). The apnea-hypopnea index (AHI) obtained with Somté was lower than with PSG: 19 (17.8) vs 21.7 (19) (p < 0.001) for scorer 1, and 16.6 (16.7) vs 20 (18.8) (p < 0.001) for scorer 2. The sensitivity of Somté for a PSG-AHI > 5 was 91% for scorer 1 and 90% for scorer 2, while specificity was 77% and 90%, respectively. The areas under the receiver operating curve for different PSG-AHI cutoff points (≥ 5, ≥ 15, and ≥ 30) were 0.81, 0.90, and 0.86, respectively, for scorer 1, and 0.90, 0.88, and 0.83 for scorer 2.
CONCLUSIONS: These data suggest that Somté is an effective device to identify sleep and respiratory variables in patients with suspected OSA.

Entities:  

Keywords:  Diagnosis; polysomnography; portable polysomnography; sleep apnea-hypopnea

Mesh:

Year:  2012        PMID: 22505861      PMCID: PMC3311413          DOI: 10.5664/jcsm.1770

Source DB:  PubMed          Journal:  J Clin Sleep Med        ISSN: 1550-9389            Impact factor:   4.062


  48 in total

1.  Increased incidence of cardiovascular disease in middle-aged men with obstructive sleep apnea: a 7-year follow-up.

Authors:  Yüksel Peker; Jan Hedner; Jeanette Norum; Holger Kraiczi; Jan Carlson
Journal:  Am J Respir Crit Care Med       Date:  2002-07-15       Impact factor: 21.405

2.  Comparison of the NovaSom QSG, a new sleep apnea home-diagnostic system, and polysomnography.

Authors:  James A Reichert; Daniel A Bloch; Elizabeth Cundiff; Bernhard A Votteri
Journal:  Sleep Med       Date:  2003-05       Impact factor: 3.492

3.  Cyclic alternating pattern and positive airway pressure titration.

Authors:  Robert Joseph Thomas
Journal:  Sleep Med       Date:  2002-07       Impact factor: 3.492

4.  Impact of different criteria for defining hypopneas in the apnea-hypopnea index.

Authors:  R L Manser; P Rochford; R J Pierce; G B Byrnes; D A Campbell
Journal:  Chest       Date:  2001-09       Impact factor: 9.410

5.  Effects of varying approaches for identifying respiratory disturbances on sleep apnea assessment.

Authors:  S Redline; V K Kapur; M H Sanders; S F Quan; D J Gottlieb; D M Rapoport; W H Bonekat; P L Smith; J P Kiley; C Iber
Journal:  Am J Respir Crit Care Med       Date:  2000-02       Impact factor: 21.405

6.  The occurrence of sleep-disordered breathing among middle-aged adults.

Authors:  T Young; M Palta; J Dempsey; J Skatrud; S Weber; S Badr
Journal:  N Engl J Med       Date:  1993-04-29       Impact factor: 91.245

7.  Interrater reliability between scorers from eight European sleep laboratories in subjects with different sleep disorders.

Authors:  Heidi Danker-Hopfe; D Kunz; G Gruber; G Klösch; J L Lorenzo; S L Himanen; B Kemp; T Penzel; J Röschke; H Dorn; A Schlögl; E Trenker; G Dorffner
Journal:  J Sleep Res       Date:  2004-03       Impact factor: 3.981

8.  Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine.

Authors:  Nancy A Collop; W McDowell Anderson; Brian Boehlecke; David Claman; Rochelle Goldberg; Daniel J Gottlieb; David Hudgel; Michael Sateia; Richard Schwab
Journal:  J Clin Sleep Med       Date:  2007-12-15       Impact factor: 4.062

9.  Simultaneous laboratory-based comparison of ResMed Autoset with polysomnography in the diagnosis of sleep apnoea/hypopnoea syndrome.

Authors:  P Mayer; J C Meurice; F Philip-Joet; A Cornette; D Rakotonanahary; N Meslier; J L Pepin; P Lévy; D Veale
Journal:  Eur Respir J       Date:  1998-10       Impact factor: 16.671

10.  Arousal frequency is associated with increased fatigue in obstructive sleep apnea.

Authors:  Herbert J Yue; Wayne Bardwell; Sonia Ancoli-Israel; José S Loredo; Joel E Dimsdale
Journal:  Sleep Breath       Date:  2009-03-25       Impact factor: 2.816

View more
  1 in total

1.  The relationship between apnoea hypopnoea index and Gensini score in patients with acute myocardial infarction undergoing emergency primary percutaneous coronary intervention.

Authors:  Cai-Ping Zhu; Tao-Ping Li; Xiao Wang; Yu-Hua Zhao; Shi-Xi Zhou; Yan Fu; Yi-Wei Jiang; Xue-Ping Xiao
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.