| Literature DB >> 22504058 |
Abstract
Serum CTX assays measure a fragment of the C-terminal telopeptide of type 1 collagen released during resorption of mature bone. Assay reagents are available in manual and automated formats and give good analytical performance. However their standardisation is not transparent and significant differences in results between methods have been demonstrated. CTX is most stable in EDTA plasma, although serum samples processed promptly would be satisfactory. sCTX shows a profound circadian rhythm, especially in non-fasting subjects; specimens should be collected from fasting patients at a well-defined time of day to minimise biological variation. Reference intervals in pre-menopausal women have been well studied but in other adult groups there is less information. Healthy children show the expected age-related variation corresponding to growth rate. Serum CTX fulfils or partially fulfils all the criteria of a reference bone turnover marker. Further studies aimed at reducing inter-method differences in results and establishing the relationships of sCTX with fracture risk and with fracture risk improvement with treatment are required.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22504058 DOI: 10.1016/j.clinbiochem.2012.03.035
Source DB: PubMed Journal: Clin Biochem ISSN: 0009-9120 Impact factor: 3.281