Literature DB >> 22503428

Aerobic treatment of dairy wastewater in an industrial three-reactor plant: effect of aeration regime on performances and on protozoan and bacterial communities.

Carlo Tocchi1, Ermanno Federici, Laura Fidati, Rodolfo Manzi, Vittorio Vinciguerra, Vittorio Vincigurerra, Maurizio Petruccioli.   

Abstract

An industrial three-reactor plant treating 45 m(3) d(-1) of dairy wastewater was monitored to investigate the effect of different aeration regimes on performance efficiency and to find relationships with bacterial and protozoan communities in the activated sludge. During the study, the plant was maintained at six different "on/off" cycles of the blower (45/15, 15/15, 15/45, 30/30, 30/45 and 30/60 min), providing between 30.2 and 90.6 kg O(2) d(-1), and the main chemical/biochemical parameters (COD, BOD, NH(4)(+), NO(2)(-), NO(3)(-), PO(4)(3-), etc.) were determined. When at least 45.4 kg O(2) d(-1) (30/45) were provided, COD removal efficiencies were always in the range 88-94% but decreased to about 70% under aeration regimes 15/45 and 30/60. Ammonium ion degradation performance was compromised only in the lowest aeration regime (15/45). Total number of protozoa and their species richness, and bacterial viable counts and denaturing gradient gel electrophoresis (DGGE) profiles were used to characterize the microbiota of the activated sludge. Cell abundances and community structures of protozoa and bacteria were very similar in the three aerated reactors but changed with the aeration regimes. In particular, the 15/45 and 30/60 regimes led to low protozoan diversity with prevalence of flagellates of the genus Trepomonas at the expense of the mobile and sessile forms and, thus, to a less efficient activated sludge as indicated by Sludge Biotic Index values (3 and 4.5 for the two regimes, respectively). The structure of the bacterial community strongly changed when the aeration regimes varied, as indicated by the low similarity values between the DGGE profiles. On the contrary, number of viable bacteria and values of the biodiversity index remained stable throughout the whole experimentation. Taken together, the results of the present study clearly indicate that aeration regime variations strongly influence the structure of both protozoan and bacterial communities and, above all, that a high biodiversity among protozoan populations in the activated sludge is prerequisite for high performances in dairy wastewater treatment.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22503428     DOI: 10.1016/j.watres.2012.03.032

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  7 in total

1.  Suitability of Sludge Biotic Index (SBI), Sludge Index (SI) and filamentous bacteria analysis for assessing activated sludge process performance: the case of piggery slaughterhouse wastewater.

Authors:  Roberta Pedrazzani; Laura Menoni; Stefano Nembrini; Livia Manili; Giorgio Bertanza
Journal:  J Ind Microbiol Biotechnol       Date:  2016-04-12       Impact factor: 3.346

2.  Ciliated protozoa community of a combined UASB-activated sludge system in southeastern Brazil.

Authors:  Isabel Cristina Vidal Siqueira-Castro; Juliane Araújo Greinert-Goulart; Renato Rossetto; José Roberto Guimarães; Regina Maura Bueno Franco
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-14       Impact factor: 4.223

3.  Treatment process and toxicities assessment of wastewater issued from anaerobic digestion of household wastes.

Authors:  Hayet Djelal; Leyla Tahrani; Salem Fathallah; Audrey Cabrol; Hedi Ben Mansour
Journal:  Environ Sci Pollut Res Int       Date:  2013-09-27       Impact factor: 4.223

4.  Dynamics of effluent treatment plant during commissioning of activated sludge process unit.

Authors:  Amit Bafana; Gulshan Kumar; Sanjay M Kashyap; Gajanan S Kanade; Vilas M Shinde
Journal:  Environ Sci Pollut Res Int       Date:  2014-09-25       Impact factor: 4.223

5.  Microbial relevant fouling in membrane bioreactors: influencing factors, characterization, and fouling control.

Authors:  Bing Wu; Anthony G Fane
Journal:  Membranes (Basel)       Date:  2012-08-15

6.  Benzene and Naphthalene Degrading Bacterial Communities in an Oil Sands Tailings Pond.

Authors:  Fauziah F Rochman; Andriy Sheremet; Ivica Tamas; Alireza Saidi-Mehrabad; Joong-Jae Kim; Xiaoli Dong; Christoph W Sensen; Lisa M Gieg; Peter F Dunfield
Journal:  Front Microbiol       Date:  2017-09-28       Impact factor: 5.640

7.  Simultaneous removal of concentrated organics, nitrogen and phosphorus nutrients by an oxygen-limited membrane bioreactor.

Authors:  Shengyun Yang; Gang Yao
Journal:  PLoS One       Date:  2018-08-30       Impact factor: 3.240

  7 in total